DIRECT BROWN COAL LIQUEFACTION IN TETRALIN. PRODUCTS YIELDS ANALYSIS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62243136%3A_____%2F18%3AN0000028" target="_blank" >RIV/62243136:_____/18:N0000028 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.icct.cz/AngiologyKlon-ICCT/media/system/2018/ICCT-2018-Proceedings.pdf" target="_blank" >http://www.icct.cz/AngiologyKlon-ICCT/media/system/2018/ICCT-2018-Proceedings.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DIRECT BROWN COAL LIQUEFACTION IN TETRALIN. PRODUCTS YIELDS ANALYSIS
Popis výsledku v původním jazyce
Direct coal liquefaction can be an alternative source of liquid fuels. The aim was to maximize the liquid product yield for DCL tests without hydrogen pressure using tetralin as solvent. Experiments were carried out in an autoclave (300 ml) in nitrogen (P = 0 bar). Tests were performed at 300, 350, 400 and 450 °C (1 h) using 1:1 or 0.4:1 of Brown Coal:Tetralin weight ratio. Then, solids, gases and liquids were sampled. The liquid product was analysed by elemental analysis, TGA, solubility in heptane and simulated distillation, the gas by GC-FID/TCD and the solids by solubility in n-heptane, xylene and trichloroethylene. The increment of temperature from 300 °C to 400 °C supposed an increment in the total amount of direct liquids products soluble in n-heptane. The maximum yield to n-heptane soluble products was found for the test carried out at 400 °C (1:1 weight ratio).
Název v anglickém jazyce
DIRECT BROWN COAL LIQUEFACTION IN TETRALIN. PRODUCTS YIELDS ANALYSIS
Popis výsledku anglicky
Direct coal liquefaction can be an alternative source of liquid fuels. The aim was to maximize the liquid product yield for DCL tests without hydrogen pressure using tetralin as solvent. Experiments were carried out in an autoclave (300 ml) in nitrogen (P = 0 bar). Tests were performed at 300, 350, 400 and 450 °C (1 h) using 1:1 or 0.4:1 of Brown Coal:Tetralin weight ratio. Then, solids, gases and liquids were sampled. The liquid product was analysed by elemental analysis, TGA, solubility in heptane and simulated distillation, the gas by GC-FID/TCD and the solids by solubility in n-heptane, xylene and trichloroethylene. The increment of temperature from 300 °C to 400 °C supposed an increment in the total amount of direct liquids products soluble in n-heptane. The maximum yield to n-heptane soluble products was found for the test carried out at 400 °C (1:1 weight ratio).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1606" target="_blank" >LO1606: Rozvoj Centra UniCRE</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS of the 6th International Conference on Chemical Technology
ISBN
978-80-86238-77-7
ISSN
2336-8128
e-ISSN
—
Počet stran výsledku
6
Strana od-do
282-287
Název nakladatele
Czech Society of Industrial Chemistry
Místo vydání
Praha
Místo konání akce
Mikulov
Datum konání akce
1. 1. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000461293800053