Improved protection scheme for shipboard microgrids based on high frequency impedance method with experimental validation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62690094%3A18450%2F25%3A50022066" target="_blank" >RIV/62690094:18450/25:50022066 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0142061524006732" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0142061524006732</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijepes.2024.110448" target="_blank" >10.1016/j.ijepes.2024.110448</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved protection scheme for shipboard microgrids based on high frequency impedance method with experimental validation
Popis výsledku v původním jazyce
his paper addresses the critical problem of fault detection in DC zonal shipboard microgrids, which is essential for ensuring system reliability and operational safety. The proposed method detects faults by utilizing the high-frequency characteristics of estimated impedance. The technique involves Fast Fourier Transform analysis of current and voltage waveforms to extract high-frequency components before and after a fault. These features help identify the system’s high-frequency impedance via a communication system. Fault detection is achieved by comparing the estimated impedance with a predefined threshold. The performance of the method is evaluated using MATLAB/Simulink simulations and experimental implementations under various scenarios. Communication between components in the DC zonal microgrid is managed using the IEC 61850 standard. Results demonstrate the method’s effectiveness in detecting faults under diverse conditions, including variations in fault resistance, dynamic load behavior, changes in photovoltaic irradiation, system configuration alterations, noise immunity, and multi-fault scenarios. The method achieves fault clearance times ranging from 0.17 ms in MATLAB/Simulink simulations to 33–45 ms in experimental tests, showing its capability to enhance fault detection in complex DC microgrid environments.
Název v anglickém jazyce
Improved protection scheme for shipboard microgrids based on high frequency impedance method with experimental validation
Popis výsledku anglicky
his paper addresses the critical problem of fault detection in DC zonal shipboard microgrids, which is essential for ensuring system reliability and operational safety. The proposed method detects faults by utilizing the high-frequency characteristics of estimated impedance. The technique involves Fast Fourier Transform analysis of current and voltage waveforms to extract high-frequency components before and after a fault. These features help identify the system’s high-frequency impedance via a communication system. Fault detection is achieved by comparing the estimated impedance with a predefined threshold. The performance of the method is evaluated using MATLAB/Simulink simulations and experimental implementations under various scenarios. Communication between components in the DC zonal microgrid is managed using the IEC 61850 standard. Results demonstrate the method’s effectiveness in detecting faults under diverse conditions, including variations in fault resistance, dynamic load behavior, changes in photovoltaic irradiation, system configuration alterations, noise immunity, and multi-fault scenarios. The method achieves fault clearance times ranging from 0.17 ms in MATLAB/Simulink simulations to 33–45 ms in experimental tests, showing its capability to enhance fault detection in complex DC microgrid environments.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrical Power & Energy Systems
ISSN
0142-0615
e-ISSN
1879-3517
Svazek periodika
164
Číslo periodika v rámci svazku
March
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
"Article number: 110448"
Kód UT WoS článku
001423757400001
EID výsledku v databázi Scopus
2-s2.0-85214237999