Geometric Ballistography - Vital Functions Monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62690094%3A18470%2F14%3A50001766" target="_blank" >RIV/62690094:18470/14:50001766 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.wseas.us/e-library/conferences/2014/Tenerife/BIOENV/BIOENV-08.pdf" target="_blank" >http://www.wseas.us/e-library/conferences/2014/Tenerife/BIOENV/BIOENV-08.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Geometric Ballistography - Vital Functions Monitoring
Popis výsledku v původním jazyce
The rather new mathematical method of biomedical data processing is presented. The technique is based on the knowledge of differential geometry. To show the efficiency of the method we demonstrate that the mechanical recoil caused by the human cardiac activity enables unobtrusive monitoring of the vital functions as well as the estimation of the aortal pulse wave velocity. Using a special bed equipped with mechanical sensors we measured the mechanical recoils of a cohort of 60 reclining patients. The obtained data have been used to extract the basic vital functions - heart and respiration rates. The results were compared with values obtained by the standard ECG measurement.
Název v anglickém jazyce
Geometric Ballistography - Vital Functions Monitoring
Popis výsledku anglicky
The rather new mathematical method of biomedical data processing is presented. The technique is based on the knowledge of differential geometry. To show the efficiency of the method we demonstrate that the mechanical recoil caused by the human cardiac activity enables unobtrusive monitoring of the vital functions as well as the estimation of the aortal pulse wave velocity. Using a special bed equipped with mechanical sensors we measured the mechanical recoils of a cohort of 60 reclining patients. The obtained data have been used to extract the basic vital functions - heart and respiration rates. The results were compared with values obtained by the standard ECG measurement.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Biomedicine and health engineering (BIHE '14)
ISBN
978-960-474-358-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
65-69
Název nakladatele
World scientific and engineering academy and society
Místo vydání
Athens
Místo konání akce
Tenerife
Datum konání akce
10. 1. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—