High-Density Network Flow Monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F63839172%3A_____%2F15%3A10130482" target="_blank" >RIV/63839172:_____/15:10130482 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/INM.2015.7140424" target="_blank" >http://dx.doi.org/10.1109/INM.2015.7140424</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/INM.2015.7140424" target="_blank" >10.1109/INM.2015.7140424</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Density Network Flow Monitoring
Popis výsledku v původním jazyce
Monitoring of high-speed networks is becoming a resource intensive task. There are dedicated flow monitoring probes built with commodity hardware support up to 10G links, but multiple 10G or even 100G optical networks are being used for transport networks and a data center connectivity. Running and maintaining many separate probes is uneconomical and time-consuming. Therefore, we explore the possibility to facilitate network interface cards (NICs) with multiple 10G interfaces to build probes which can replace many existing boxes, leading to reduced management and operational costs. The monitoring performance is critical for such a high-density solution. We use two custom-built, FPGA-based NICs, each with eight 10G interfaces to test current CPU limits and to propose improvements for the near future commodity NICs.
Název v anglickém jazyce
High-Density Network Flow Monitoring
Popis výsledku anglicky
Monitoring of high-speed networks is becoming a resource intensive task. There are dedicated flow monitoring probes built with commodity hardware support up to 10G links, but multiple 10G or even 100G optical networks are being used for transport networks and a data center connectivity. Running and maintaining many separate probes is uneconomical and time-consuming. Therefore, we explore the possibility to facilitate network interface cards (NICs) with multiple 10G interfaces to build probes which can replace many existing boxes, leading to reduced management and operational costs. The monitoring performance is critical for such a high-density solution. We use two custom-built, FPGA-based NICs, each with eight 10G interfaces to test current CPU limits and to propose improvements for the near future commodity NICs.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA03010561" target="_blank" >TA03010561: Distribuovaný systém pro komplexní monitorování vysokorychlostních sítí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2015 IFIP/IEEE International Symposium on Integrated Network Management (IM 2015)
ISBN
978-3-901882-76-0
ISSN
1573-0077
e-ISSN
—
Počet stran výsledku
6
Strana od-do
996-1001
Název nakladatele
IEEE Xplore Digital Library
Místo vydání
Ottawa, Canada
Místo konání akce
Ottawa, Canada
Datum konání akce
11. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—