Comparison of Interferometry Based and Polarization Based Sensing Systems for Use in Fiber Infrastructure Protection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F63839172%3A_____%2F17%3A10132960" target="_blank" >RIV/63839172:_____/17:10132960 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/17:PU125430
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8215255/" target="_blank" >https://ieeexplore.ieee.org/document/8215255/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/FOAN.2017.8215255" target="_blank" >10.1109/FOAN.2017.8215255</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Interferometry Based and Polarization Based Sensing Systems for Use in Fiber Infrastructure Protection
Popis výsledku v původním jazyce
Almost all data transmissions over long distances are transmitted through optical fibers. Fiber infrastructure is therefore very important and is necessary to protect it against fiber cuts caused e.g. by digging activity. Many network operators seeking appropriate solution for self protecting infrastructure system. We performed comparative measurement of the polarization based sensing system and the interferometry based sensing system to determine the sensitivity and accuracy of both systems. The results confirmed theoretical assumptions that both systems are suitable for strain measurement and the interferometry based sensing systems are more sensitive.
Název v anglickém jazyce
Comparison of Interferometry Based and Polarization Based Sensing Systems for Use in Fiber Infrastructure Protection
Popis výsledku anglicky
Almost all data transmissions over long distances are transmitted through optical fibers. Fiber infrastructure is therefore very important and is necessary to protect it against fiber cuts caused e.g. by digging activity. Many network operators seeking appropriate solution for self protecting infrastructure system. We performed comparative measurement of the polarization based sensing system and the interferometry based sensing system to determine the sensitivity and accuracy of both systems. The results confirmed theoretical assumptions that both systems are suitable for strain measurement and the interferometry based sensing systems are more sensitive.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
FOAN2017
ISBN
978-1-5386-2413-5
ISSN
2378-8488
e-ISSN
neuvedeno
Počet stran výsledku
3
Strana od-do
1-3
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Mnichov
Datum konání akce
6. 11. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000425164500010