Ovlivnění negativních příznaků schizofrenie prostřednictvím repetitivní transkraniální magnetické stimulace: kazuistické sdělení
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F07%3A%230000073" target="_blank" >RIV/65269705:_____/07:#0000073 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influencing negative symptoms of schizophrenia with repetitive transcranial magentic stimulation: a case study
Popis výsledku v původním jazyce
The present trial was designed to investigate the influence of rTMS on negative schizophrenic symptoms using high frequency stimulation of the left dorsolateral prefrontal cortex in a simple blind randomised design. Methods: The study was carried out ona 42-year-old schizophrenic patient (paranoid subtype) with prominent negative symptoms who was firstly treated with sham rTMS during the first three weeks and then with real high frequency during the following three weeks. He was rated before and afterthe sham and after the real rTMS therapy for positive, negative and depressive symptoms. Results: rTMS was superior to sham treatment in reduction of negative and depressive symptoms. Conclusion: High frequency rTMS applied over the left dorsolateral prefrontal cortex led to a reduction of severity of negative symptoms in a patient with chronic schizophrenia and may be beneficial as an augmentation option to antipsychotics in the treatment of negative symptoms of schizophrenia.
Název v anglickém jazyce
Influencing negative symptoms of schizophrenia with repetitive transcranial magentic stimulation: a case study
Popis výsledku anglicky
The present trial was designed to investigate the influence of rTMS on negative schizophrenic symptoms using high frequency stimulation of the left dorsolateral prefrontal cortex in a simple blind randomised design. Methods: The study was carried out ona 42-year-old schizophrenic patient (paranoid subtype) with prominent negative symptoms who was firstly treated with sham rTMS during the first three weeks and then with real high frequency during the following three weeks. He was rated before and afterthe sham and after the real rTMS therapy for positive, negative and depressive symptoms. Results: rTMS was superior to sham treatment in reduction of negative and depressive symptoms. Conclusion: High frequency rTMS applied over the left dorsolateral prefrontal cortex led to a reduction of severity of negative symptoms in a patient with chronic schizophrenia and may be beneficial as an augmentation option to antipsychotics in the treatment of negative symptoms of schizophrenia.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FL - Psychiatrie, sexuologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR8472" target="_blank" >NR8472: Ovlivnění kognitivního deficitu u nemocných s depresivní poruchou pomocí repetitivní transkraniální magnetické stimulace (rTMS) v podmínkách jednoduše slepé, randomizované studie.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta neuropsychiatrica
ISSN
0924-2708
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
AU - Austrálie
Počet stran výsledku
3
Strana od-do
53-55
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—