Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F09%3A%230000850" target="_blank" >RIV/65269705:_____/09:#0000850 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/65269705:_____/09:#0001510 RIV/00216224:14110/09:00059847
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement
Popis výsledku v původním jazyce
Decreased intrasubject variability of QTc values is needed to increase the power and reduce the size of the so-called thorough QT studies. One source of QTc variability is the lack of systematic measurements when electrocardiograms (ECG) with closely matching morphologies are not measured in an exactly corresponding way. The inaccuracy can be eliminated by postprocessing of QT measurements by ECG pattern matching. This study tested the effects of pattern matching in ECG measurements in two populations of healthy subjects (n = 48 + 56) and in a population of patients with advanced Parkinson's disease (n = 130) in whom both day-time and night-time data were available. Intrasubject QTc variability was measured by intrasubject standard deviations (SD) of QTc values obtained with manual measurements before and after pattern-matching measurement alignments. In each subject, QT values (n = 230-320) in one drug-free long-term ECG recording were evaluated. T
Název v anglickém jazyce
Systematic comparisons of electrocardiographic morphology increase the precision of QT interval measurement
Popis výsledku anglicky
Decreased intrasubject variability of QTc values is needed to increase the power and reduce the size of the so-called thorough QT studies. One source of QTc variability is the lack of systematic measurements when electrocardiograms (ECG) with closely matching morphologies are not measured in an exactly corresponding way. The inaccuracy can be eliminated by postprocessing of QT measurements by ECG pattern matching. This study tested the effects of pattern matching in ECG measurements in two populations of healthy subjects (n = 48 + 56) and in a population of patients with advanced Parkinson's disease (n = 130) in whom both day-time and night-time data were available. Intrasubject QTc variability was measured by intrasubject standard deviations (SD) of QTc values obtained with manual measurements before and after pattern-matching measurement alignments. In each subject, QT values (n = 230-320) in one drug-free long-term ECG recording were evaluated. T
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Pacing & Clinical Electrophysiology
ISSN
0147-8389
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—