0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F18%3A00068782" target="_blank" >RIV/65269705:_____/18:00068782 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/18:00103658
Výsledek na webu
<a href="https://www.ahajournals.org/doi/pdf/10.1161/CIRCULATIONAHA.117.028901" target="_blank" >https://www.ahajournals.org/doi/pdf/10.1161/CIRCULATIONAHA.117.028901</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCULATIONAHA.117.028901" target="_blank" >10.1161/CIRCULATIONAHA.117.028901</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction
Popis výsledku v původním jazyce
Background: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. Methods: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m(2), and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. Results: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. Conclusions: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.
Název v anglickém jazyce
0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction
Popis výsledku anglicky
Background: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. Methods: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m(2), and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. Results: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. Conclusions: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation
ISSN
0009-7322
e-ISSN
—
Svazek periodika
137
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
436-451
Kód UT WoS článku
000423565200005
EID výsledku v databázi Scopus
2-s2.0-85048400833