Bronchoalveolar lavage fluid and serum 1,3-β-D-glucan testing for invasive pulmonary aspergillosis diagnosis in hematological patients: the role of factors affecting assay performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F20%3A00073187" target="_blank" >RIV/65269705:_____/20:00073187 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.nature.com/articles/s41598-020-75132-3" target="_blank" >https://www.nature.com/articles/s41598-020-75132-3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-020-75132-3" target="_blank" >10.1038/s41598-020-75132-3</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bronchoalveolar lavage fluid and serum 1,3-β-D-glucan testing for invasive pulmonary aspergillosis diagnosis in hematological patients: the role of factors affecting assay performance
Popis výsledku v původním jazyce
Invasive fungal disease (IFD) early diagnosis improves hematological patient survival. Non-culture-based methods may reduce diagnostic time to identify IFD. As complex data on the value of 1,3-β-d-glucan (BDG) from bronchoalveolar lavage fluid (BALF) compared to serum for the most frequent invasive pulmonary aspergillosis (IPA) diagnosis are scarce, particularly including evaluation of potential factors adversely affecting BDG assay, we provided prospective single-center analysis evaluating 172 episodes of pulmonary infiltrates with BDG detection in BALF and serum samples collected in parallel among hematological patients from 2006 to 2015. Proven and probable IPA were documented in 13.4% of the episodes. Sensitivity (SEN), specificity (SPE), positive and negative predictive value (PPV; NPV), and diagnostic odds ratio (DOR) of the BDG assay using standard (80 pg/ml) cut-off for BALF were: 56.5%; 83.2%; 34.2%; 92.5%, and 6.5, respectively, and for serum were: 56.5%; 82.6%; 33.3%; 92.5%, and 6.2, respectively. The same BDG assay parameters employing a calculated optimal cut-off for BALF (39 pg/ml) were: 78.3%; 72.5%; 30.5%; 95.6%, and 9.5, respectively; and for serum (40 pg/ml) were: 73.9%; 69.1%; 27.0%; 94.5%, and 6.3, respectively. While identifying acceptable SEN, SPE, and DOR, yet low PPV of both BALF and serum BDG assay for IPA diagnosis, neither the combination of both materials nor the new optimal BDG cut-off led to significant test quality improvement. Absolute neutrophil count and aspirated BALF volume with a significant trend affected BDG assay performance. The BDG test did not outperform galactomannan assay.
Název v anglickém jazyce
Bronchoalveolar lavage fluid and serum 1,3-β-D-glucan testing for invasive pulmonary aspergillosis diagnosis in hematological patients: the role of factors affecting assay performance
Popis výsledku anglicky
Invasive fungal disease (IFD) early diagnosis improves hematological patient survival. Non-culture-based methods may reduce diagnostic time to identify IFD. As complex data on the value of 1,3-β-d-glucan (BDG) from bronchoalveolar lavage fluid (BALF) compared to serum for the most frequent invasive pulmonary aspergillosis (IPA) diagnosis are scarce, particularly including evaluation of potential factors adversely affecting BDG assay, we provided prospective single-center analysis evaluating 172 episodes of pulmonary infiltrates with BDG detection in BALF and serum samples collected in parallel among hematological patients from 2006 to 2015. Proven and probable IPA were documented in 13.4% of the episodes. Sensitivity (SEN), specificity (SPE), positive and negative predictive value (PPV; NPV), and diagnostic odds ratio (DOR) of the BDG assay using standard (80 pg/ml) cut-off for BALF were: 56.5%; 83.2%; 34.2%; 92.5%, and 6.5, respectively, and for serum were: 56.5%; 82.6%; 33.3%; 92.5%, and 6.2, respectively. The same BDG assay parameters employing a calculated optimal cut-off for BALF (39 pg/ml) were: 78.3%; 72.5%; 30.5%; 95.6%, and 9.5, respectively; and for serum (40 pg/ml) were: 73.9%; 69.1%; 27.0%; 94.5%, and 6.3, respectively. While identifying acceptable SEN, SPE, and DOR, yet low PPV of both BALF and serum BDG assay for IPA diagnosis, neither the combination of both materials nor the new optimal BDG cut-off led to significant test quality improvement. Absolute neutrophil count and aspirated BALF volume with a significant trend affected BDG assay performance. The BDG test did not outperform galactomannan assay.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10700 - Other natural sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
17963
Kód UT WoS článku
000585150000021
EID výsledku v databázi Scopus
2-s2.0-85093102338