Contrast-Enhanced Ultrasonography for Differential Diagnosis of Benign and Malignant Thyroid Lesions: Single-Institutional Prospective Study of Qualitative and Quantitative CEUS Characteristics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F22%3A00076608" target="_blank" >RIV/65269705:_____/22:00076608 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/22:00126462
Výsledek na webu
<a href="https://www.hindawi.com/journals/cmmi/2022/8229445/" target="_blank" >https://www.hindawi.com/journals/cmmi/2022/8229445/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2022/8229445" target="_blank" >10.1155/2022/8229445</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Contrast-Enhanced Ultrasonography for Differential Diagnosis of Benign and Malignant Thyroid Lesions: Single-Institutional Prospective Study of Qualitative and Quantitative CEUS Characteristics
Popis výsledku v původním jazyce
Objectives. To extend and revise the diagnostic value of contrast-enhanced ultrasonography (CEUS) for differentiation between malignant and benign thyroid nodules. Methods. This single-institution prospective study aims to compare CEUS qualitative and objective quantitative parameters in benign and malignant thyroid nodules. Consecutive cohort of 100 patients was examined by CEUS, 68 out of them were further analysed in detail. All included patients underwent cytological and/or histopathological verification of the diagnosis. Results. Fifty-five (81%) thyroid nodules were benign, and 13 (19%) were malignant. Ring enhancement pattern was strongly associated with a benign aetiology (positive predictive value 100%) and heterogeneous enhancement pattern with malignant aetiology (positive predictive value 72.7%). The shape of the TIC (time-intensity curve) was more often identical in the benign lesion (98.2%) than in malignant lesions (69.2%), p=0.004. Conclusions. This study indicates that CEUS enhancement patterns were significantly different in benign and malignant lesions. Ring enhancement was a very strong indicator of benign lesions, whereas heterogeneous enhancement was valuable to detect malignant lesions.
Název v anglickém jazyce
Contrast-Enhanced Ultrasonography for Differential Diagnosis of Benign and Malignant Thyroid Lesions: Single-Institutional Prospective Study of Qualitative and Quantitative CEUS Characteristics
Popis výsledku anglicky
Objectives. To extend and revise the diagnostic value of contrast-enhanced ultrasonography (CEUS) for differentiation between malignant and benign thyroid nodules. Methods. This single-institution prospective study aims to compare CEUS qualitative and objective quantitative parameters in benign and malignant thyroid nodules. Consecutive cohort of 100 patients was examined by CEUS, 68 out of them were further analysed in detail. All included patients underwent cytological and/or histopathological verification of the diagnosis. Results. Fifty-five (81%) thyroid nodules were benign, and 13 (19%) were malignant. Ring enhancement pattern was strongly associated with a benign aetiology (positive predictive value 100%) and heterogeneous enhancement pattern with malignant aetiology (positive predictive value 72.7%). The shape of the TIC (time-intensity curve) was more often identical in the benign lesion (98.2%) than in malignant lesions (69.2%), p=0.004. Conclusions. This study indicates that CEUS enhancement patterns were significantly different in benign and malignant lesions. Ring enhancement was a very strong indicator of benign lesions, whereas heterogeneous enhancement was valuable to detect malignant lesions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Contrast Media and Molecular Imaging
ISSN
1555-4309
e-ISSN
1555-4317
Svazek periodika
2022
Číslo periodika v rámci svazku
Apr
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
8229445
Kód UT WoS článku
000822809100002
EID výsledku v databázi Scopus
2-s2.0-85129503024