Anterior Chamber Iris-Fixated Phakic Intraocular Lens Implantation for Treatment of High Anisometropia in Children: Long-term Results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F23%3A00077519" target="_blank" >RIV/65269705:_____/23:00077519 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/23:00130141 RIV/00216208:11130/23:10446131 RIV/00064203:_____/23:10446131
Výsledek na webu
<a href="https://journals.healio.com/doi/full/10.3928/01913913-20220610-02" target="_blank" >https://journals.healio.com/doi/full/10.3928/01913913-20220610-02</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3928/01913913-20220610-02" target="_blank" >10.3928/01913913-20220610-02</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Anterior Chamber Iris-Fixated Phakic Intraocular Lens Implantation for Treatment of High Anisometropia in Children: Long-term Results
Popis výsledku v původním jazyce
Purpose: To evaluate the long-term efficacy of anterior chamber iris-fixated phakic intraocular lens (PIOL) implantation in the treatment of high myopic (> -9.00 diopters [D]) or hyperopic (> +6.00 D) anisometropia in children with intolerance to spectacles or contact lenses. Methods: A total of 58 children with anisometropic myopia (range: -9.25 to-18.50 diopters [D]) and 13 children with anisometropic hyperopia (range: +6.00 to +8.50 D) underwent unilateral iris-claw PIOL implantation from 2008 to 2018. The mean age was 6.7 years. The mean follow-up was 38.5 months. Target refraction was emmetropia. Results: The cycloplegic refraction (mean spherical equivalent) improved from -12.47 D (range:-9.25 to-18.50 D) to -0.73 D (range: +0.75 to -1.50 D) in myopic eyes and reduced from +7.15 D (range: +6.00 to +8.50 D) to +0.94 D (range: -0.50 to + 1.75 D) in hyperopic eyes. Eighty-four percent of eyes were corrected to within +/- 1.00 D of emmetropia. The mean uncorrected distance visual acuity (UDVA) improved from 1.74 +/- 0.36 to 0.45 +/- 0.28 logarithm of the minimum angle of resolution (logMAR) (P = .0014). The mean corrected distance visual acuity (CDVA) changed from 0.68 +/- 0.32 to 0.27 +/- 0.15 logMAR (P = .02179). The safety index was 2.18 and the efficacy index was 1.51. The mean preoperative endothelial cell count of 2,874.7 cells/mm(2) changed to 2,685.3 cells/mm(2) at 2 to 6 years postoperatively. Binocular vision quality was improved in 55 patients. No patient had serious complications or lost any Snellen lines of CDVA. Conclusions: Iris-fixated PIOL implantation is an effective and safe method in the treatment of high anisometropic myopia and hyperopia and amblyopia in pediatric patients who are noncompliant with spectacles or contact lenses.
Název v anglickém jazyce
Anterior Chamber Iris-Fixated Phakic Intraocular Lens Implantation for Treatment of High Anisometropia in Children: Long-term Results
Popis výsledku anglicky
Purpose: To evaluate the long-term efficacy of anterior chamber iris-fixated phakic intraocular lens (PIOL) implantation in the treatment of high myopic (> -9.00 diopters [D]) or hyperopic (> +6.00 D) anisometropia in children with intolerance to spectacles or contact lenses. Methods: A total of 58 children with anisometropic myopia (range: -9.25 to-18.50 diopters [D]) and 13 children with anisometropic hyperopia (range: +6.00 to +8.50 D) underwent unilateral iris-claw PIOL implantation from 2008 to 2018. The mean age was 6.7 years. The mean follow-up was 38.5 months. Target refraction was emmetropia. Results: The cycloplegic refraction (mean spherical equivalent) improved from -12.47 D (range:-9.25 to-18.50 D) to -0.73 D (range: +0.75 to -1.50 D) in myopic eyes and reduced from +7.15 D (range: +6.00 to +8.50 D) to +0.94 D (range: -0.50 to + 1.75 D) in hyperopic eyes. Eighty-four percent of eyes were corrected to within +/- 1.00 D of emmetropia. The mean uncorrected distance visual acuity (UDVA) improved from 1.74 +/- 0.36 to 0.45 +/- 0.28 logarithm of the minimum angle of resolution (logMAR) (P = .0014). The mean corrected distance visual acuity (CDVA) changed from 0.68 +/- 0.32 to 0.27 +/- 0.15 logMAR (P = .02179). The safety index was 2.18 and the efficacy index was 1.51. The mean preoperative endothelial cell count of 2,874.7 cells/mm(2) changed to 2,685.3 cells/mm(2) at 2 to 6 years postoperatively. Binocular vision quality was improved in 55 patients. No patient had serious complications or lost any Snellen lines of CDVA. Conclusions: Iris-fixated PIOL implantation is an effective and safe method in the treatment of high anisometropic myopia and hyperopia and amblyopia in pediatric patients who are noncompliant with spectacles or contact lenses.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Pediatric Ophthalmology & Strabismus
ISSN
0191-3913
e-ISSN
1938-2405
Svazek periodika
60
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
203-209
Kód UT WoS článku
000838851100001
EID výsledku v databázi Scopus
2-s2.0-85160454574