Interlaboratory assays from the fungal PCR Initiative and the Modimucor Study Group to improve qPCR detection of Mucorales DNA in serum: one more step toward standardization
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F25%3A00081021" target="_blank" >RIV/65269705:_____/25:00081021 - isvavai.cz</a>
Výsledek na webu
<a href="https://journals.asm.org/doi/full/10.1128/jcm.01525-24" target="_blank" >https://journals.asm.org/doi/full/10.1128/jcm.01525-24</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1128/jcm.01525-24" target="_blank" >10.1128/jcm.01525-24</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interlaboratory assays from the fungal PCR Initiative and the Modimucor Study Group to improve qPCR detection of Mucorales DNA in serum: one more step toward standardization
Popis výsledku v původním jazyce
The aim of this study was to identify parameters influencing DNA extraction and PCR amplification efficiencies in an attempt to standardize Mucorales qPCR. The Fungal PCR Initiative Mucorales Laboratory Working Group distributed two panels of simulated samples to 26 laboratories: Panel A (six sera spiked with Mucorales DNA and one negative control serum) and Panel B (six Mucorales DNA extracts). Panel A underwent DNA extraction in each laboratory according to the local procedure and were sent to a central laboratory for testing using three different qPCR techniques: one in-house qPCR assay and two commercial assays (MucorGenius and Fungiplex). Panel B DNA extracts were PCR amplified in each laboratory using local procedures: nine in-house qPCR assays and two commercial kits (MucorGenius and MycoGENIE). All data were compiled and anonymously analyzed at the central laboratory. For Panel A, a total of six different automated platforms and five manual extraction methods were used. Positive rates were 64%, 70%, and 89%, for the MucorGenius, Fungiplex, and the in-house qPCR assay, respectively. Using a large volume of serum for DNA extraction provided the highest analytical sensitivity (82.5% for 1 mL compared with 62.7% for smaller volumes, P < 0.01). For Panel B, five in-house qPCR assays and two commercial kits had >78% positivity. Using larger PCR input volumes (>= 7 mu L) was associated with the highest sensitivity at 95.5% compared to 58.3% when lower input volumes were used (P < 0.01). Using larger sample volumes for nucleic acid extraction and DNA template volumes for PCR amplification significantly improves the performance of Mucorales qPCR when testing serum.
Název v anglickém jazyce
Interlaboratory assays from the fungal PCR Initiative and the Modimucor Study Group to improve qPCR detection of Mucorales DNA in serum: one more step toward standardization
Popis výsledku anglicky
The aim of this study was to identify parameters influencing DNA extraction and PCR amplification efficiencies in an attempt to standardize Mucorales qPCR. The Fungal PCR Initiative Mucorales Laboratory Working Group distributed two panels of simulated samples to 26 laboratories: Panel A (six sera spiked with Mucorales DNA and one negative control serum) and Panel B (six Mucorales DNA extracts). Panel A underwent DNA extraction in each laboratory according to the local procedure and were sent to a central laboratory for testing using three different qPCR techniques: one in-house qPCR assay and two commercial assays (MucorGenius and Fungiplex). Panel B DNA extracts were PCR amplified in each laboratory using local procedures: nine in-house qPCR assays and two commercial kits (MucorGenius and MycoGENIE). All data were compiled and anonymously analyzed at the central laboratory. For Panel A, a total of six different automated platforms and five manual extraction methods were used. Positive rates were 64%, 70%, and 89%, for the MucorGenius, Fungiplex, and the in-house qPCR assay, respectively. Using a large volume of serum for DNA extraction provided the highest analytical sensitivity (82.5% for 1 mL compared with 62.7% for smaller volumes, P < 0.01). For Panel B, five in-house qPCR assays and two commercial kits had >78% positivity. Using larger PCR input volumes (>= 7 mu L) was associated with the highest sensitivity at 95.5% compared to 58.3% when lower input volumes were used (P < 0.01). Using larger sample volumes for nucleic acid extraction and DNA template volumes for PCR amplification significantly improves the performance of Mucorales qPCR when testing serum.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10606 - Microbiology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Clinical Microbiology
ISSN
0095-1137
e-ISSN
1098-660X
Svazek periodika
63
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
15
Strana od-do
nestránkováno
Kód UT WoS článku
001386374600001
EID výsledku v databázi Scopus
2-s2.0-85219028915