Measurements of CO2 fluxes were carried out using two different techniques -eddy covariance (EC) and open system gas exchange chamber (OC) during two years period at three different grassland sites. OC measurements were made during fourteen measurementscampaigns. We found good agreements between the OC and EC CO2 flux values (n=63, r2=0.5323, OC FCO2=-0.6408+0.9508EC). The OC FH2O values were consistently lower that those measured by the EC technique, probably caused by the air stream difference insideand outside the chamber. Adjusting flow rate within the chamber to the natural conditions would be necessary in future OC measurements. In comparison with EC, the OC proved to be a good tool for gas exchange measurements in grassland ecosystems.
Název v anglickém jazyce
Comparison of CO2 and H2O fluxes over grassland vegetations measured by the eddy-covariance technique and by open system chamber
Popis výsledku anglicky
Measurements of CO2 fluxes were carried out using two different techniques -eddy covariance (EC) and open system gas exchange chamber (OC) during two years period at three different grassland sites. OC measurements were made during fourteen measurementscampaigns. We found good agreements between the OC and EC CO2 flux values (n=63, r2=0.5323, OC FCO2=-0.6408+0.9508EC). The OC FH2O values were consistently lower that those measured by the EC technique, probably caused by the air stream difference insideand outside the chamber. Adjusting flow rate within the chamber to the natural conditions would be necessary in future OC measurements. In comparison with EC, the OC proved to be a good tool for gas exchange measurements in grassland ecosystems.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EH - Ekologie – společenstva
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Photosynthetica
ISSN
0300-3604
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000247190100019
EID výsledku v databázi Scopus
—