Dynamics of temperature normalized stem CO2 efflux in Norway Spruce stand
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67179843%3A_____%2F11%3A00366891" target="_blank" >RIV/67179843:_____/11:00366891 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dynamics of temperature normalized stem CO2 efflux in Norway Spruce stand
Popis výsledku v původním jazyce
Continuous measurements of stem CO2 efflux were carried out by an automated system during the growing season in 2006?2009. Further measured characteristics were stem temperature, stem increment and precipitations. Stem CO2 efflux was in tight relationship with changes in temperature with the mean coefficient of determination of 0.76. This infers that temperature was the main factor driving changes in CO2 efflux during the season. To eliminate effect of temperature and determine other factors influencingstem CO2 efflux, CO2 efflux was normalized for temperature of 10 °C (R10). Basic seasonal course of R10 followed the pattern of stem growth rate with its maxima in June and July. The other factor effect, which was possible to determine, was presence ofrainfall. Rainfall strong enough caused mostly increase in R10. This effect was the most significant when the R10 course had a decreasing trend in the second part of the growing season.
Název v anglickém jazyce
Dynamics of temperature normalized stem CO2 efflux in Norway Spruce stand
Popis výsledku anglicky
Continuous measurements of stem CO2 efflux were carried out by an automated system during the growing season in 2006?2009. Further measured characteristics were stem temperature, stem increment and precipitations. Stem CO2 efflux was in tight relationship with changes in temperature with the mean coefficient of determination of 0.76. This infers that temperature was the main factor driving changes in CO2 efflux during the season. To eliminate effect of temperature and determine other factors influencingstem CO2 efflux, CO2 efflux was normalized for temperature of 10 °C (R10). Basic seasonal course of R10 followed the pattern of stem growth rate with its maxima in June and July. The other factor effect, which was possible to determine, was presence ofrainfall. Rainfall strong enough caused mostly increase in R10. This effect was the most significant when the R10 course had a decreasing trend in the second part of the growing season.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EH - Ekologie – společenstva
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
ISSN
1211-8516
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
121-125
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—