Low-noise magnetic observatory variometer with race-track sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985530%3A_____%2F16%3A00466154" target="_blank" >RIV/67985530:_____/16:00466154 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/108/1/012026" target="_blank" >http://dx.doi.org/10.1088/1757-899X/108/1/012026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/108/1/012026" target="_blank" >10.1088/1757-899X/108/1/012026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Low-noise magnetic observatory variometer with race-track sensors
Popis výsledku v původním jazyce
We present a low-noise, high-stability observatory magnetometer with race-track sensors, as developed by the Czech Technical University in Prague for National Observatory of Athens. As opposed to the standard instruments, we used our novel race-track fluxgate sensors with planar oval core which were cut by state-of-the art pico-second UV-laser. The noise performance of the complete electronics and sensor chain is below 6 pT/v Hz @ 1 Hz. The electronics uses 24-bit 200-Hz A/D converter with simultaneous sampling and all digital processing is done in FPGA. The variometer with the sensors mounted on a MACOR cube has been successfully calibrated by scalar method.
Název v anglickém jazyce
Low-noise magnetic observatory variometer with race-track sensors
Popis výsledku anglicky
We present a low-noise, high-stability observatory magnetometer with race-track sensors, as developed by the Czech Technical University in Prague for National Observatory of Athens. As opposed to the standard instruments, we used our novel race-track fluxgate sensors with planar oval core which were cut by state-of-the art pico-second UV-laser. The noise performance of the complete electronics and sensor chain is below 6 pT/v Hz @ 1 Hz. The electronics uses 24-bit 200-Hz A/D converter with simultaneous sampling and all digital processing is done in FPGA. The variometer with the sensors mounted on a MACOR cube has been successfully calibrated by scalar method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DE - Zemský magnetismus, geodesie, geografie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2015079" target="_blank" >LM2015079: Distribuovaný systém observatorních a terénních měření geofyzikálních polí</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
4
Strana od-do
"012026/1"-"012026/4"
Název nakladatele
IOP Publishing
Místo vydání
Bristol
Místo konání akce
Mykonos
Datum konání akce
27. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000376204700026