aktivityMonte Carlo simulation of PET images for injection dose optimization
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985556%3A_____%2F11%3A00369540" target="_blank" >RIV/67985556:_____/11:00369540 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
aktivityMonte Carlo simulation of PET images for injection dose optimization
Popis výsledku v původním jazyce
When a patient is examined by positron emission tomography, radiotracer dose amount has to be determined. However, the rules used nowadays do not correspond with practical experience. Slim patients are given unnecessary amount of radiotracer and obese patients would need more activity to produce images of sufficient quality. We have built a model of a particular PET scanner and approximated human trunk, which is our region of interest, by a cylindrical model with segments of liver, outer adipose tissueand the rest. We have performed Monte Carlo simulations of PET imaging using the GATE simulation package. Under reasonably simplifying assumptions and for special parameters, we have developed curves, which recommend amount of injected activity based onbody parameters to give PET images of constant quality. The dependence qualitatively differs from the rules used in clinical practice nowadays and the results indicate potential for improvement
Název v anglickém jazyce
aktivityMonte Carlo simulation of PET images for injection dose optimization
Popis výsledku anglicky
When a patient is examined by positron emission tomography, radiotracer dose amount has to be determined. However, the rules used nowadays do not correspond with practical experience. Slim patients are given unnecessary amount of radiotracer and obese patients would need more activity to produce images of sufficient quality. We have built a model of a particular PET scanner and approximated human trunk, which is our region of interest, by a cylindrical model with segments of liver, outer adipose tissueand the rest. We have performed Monte Carlo simulations of PET imaging using the GATE simulation package. Under reasonably simplifying assumptions and for special parameters, we have developed curves, which recommend amount of injected activity based onbody parameters to give PET images of constant quality. The dependence qualitatively differs from the rules used in clinical practice nowadays and the results indicate potential for improvement
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BD - Teorie informace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0572" target="_blank" >1M0572: Data, algoritmy, rozhodování</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computational Vision and Medical Image Processing: VipIMAGE 2011
ISBN
978-0-415-68395-1
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
Taylor and Francis
Místo vydání
London
Místo konání akce
Olhao, Algarve
Datum konání akce
12. 10. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—