On the high energy cut-off of accreting sources: Is general relativity relevant?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985815%3A_____%2F18%3A00496101" target="_blank" >RIV/67985815:_____/18:00496101 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1093/mnras/stx2987" target="_blank" >http://dx.doi.org/10.1093/mnras/stx2987</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/mnras/stx2987" target="_blank" >10.1093/mnras/stx2987</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the high energy cut-off of accreting sources: Is general relativity relevant?
Popis výsledku v původním jazyce
The hard X-ray emission observed in accreting compact sources is believed to be produced by inverse Compton scattering of soft photons arising from the accretion disc by energetic electrons thermally distributed above the disc, the so-called X-ray corona. Many independent observations suggest that such coronae should be compact and located very close to the black hole. In this case, general relativistic (GR) effects should play an important role to the continuum X-ray emission from these sources, and, in particular, in the observed high energy cut-off, which is a measure of the intrinsic temperature of the corona. Our results show that the energy shift between the observed and intrinsic high energy cut-off due to GR effects can be as large as two to eight times, depending on the geometry and size of the corona as well as its inclination. We provide estimates of this energy shift in the case of a lamp-post and a flat, rotating corona, around a Kerr and a Schwartzschild black hole, for various inclinations, and coronal sizes. These values could be useful to correct the observed high energy cut-off and/or coronal temperatures, either in the case of individual or large sample of objects.
Název v anglickém jazyce
On the high energy cut-off of accreting sources: Is general relativity relevant?
Popis výsledku anglicky
The hard X-ray emission observed in accreting compact sources is believed to be produced by inverse Compton scattering of soft photons arising from the accretion disc by energetic electrons thermally distributed above the disc, the so-called X-ray corona. Many independent observations suggest that such coronae should be compact and located very close to the black hole. In this case, general relativistic (GR) effects should play an important role to the continuum X-ray emission from these sources, and, in particular, in the observed high energy cut-off, which is a measure of the intrinsic temperature of the corona. Our results show that the energy shift between the observed and intrinsic high energy cut-off due to GR effects can be as large as two to eight times, depending on the geometry and size of the corona as well as its inclination. We provide estimates of this energy shift in the case of a lamp-post and a flat, rotating corona, around a Kerr and a Schwartzschild black hole, for various inclinations, and coronal sizes. These values could be useful to correct the observed high energy cut-off and/or coronal temperatures, either in the case of individual or large sample of objects.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10308 - Astronomy (including astrophysics,space science)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monthly Notices of the Royal Astronomical Society
ISSN
1365-2966
e-ISSN
—
Svazek periodika
475
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
2045-2050
Kód UT WoS článku
000427345900041
EID výsledku v databázi Scopus
2-s2.0-85045119258