Zpřesnění odhadu objemu z konfokálních řezů po aplikaci dekonvoluce obrazu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985823%3A_____%2F04%3A00103084" target="_blank" >RIV/67985823:_____/04:00103084 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improvement in volume estimation from confocal sections after image deconvolution
Popis výsledku v původním jazyce
The confocal fluorescence microscope is considered as a true volume imager but intrinsic imaging properties of the optical scheme yield a corrupted image that can hamper quantitative analysis of successive image planes. By a post-image collection restoration we obtained an estimate of the true object, utilizing the Point Spread Function (PSF).The PSF was measured and predicted to have a mathematical and physical model of the image-formation process. We used the regularized Iterative Constrained TykhonovMiller restoration algorithm for solving the inverse problem. In order to compare the effective improvement in the quantitative image information analysis, we measured the volume of reference objects before and after image restoration, using the isotropic fakir stereological method
Název v anglickém jazyce
Improvement in volume estimation from confocal sections after image deconvolution
Popis výsledku anglicky
The confocal fluorescence microscope is considered as a true volume imager but intrinsic imaging properties of the optical scheme yield a corrupted image that can hamper quantitative analysis of successive image planes. By a post-image collection restoration we obtained an estimate of the true object, utilizing the Point Spread Function (PSF).The PSF was measured and predicted to have a mathematical and physical model of the image-formation process. We used the regularized Iterative Constrained TykhonovMiller restoration algorithm for solving the inverse problem. In order to compare the effective improvement in the quantitative image information analysis, we measured the volume of reference objects before and after image restoration, using the isotropic fakir stereological method
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EA - Morfologické obory a cytologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microscopy Research Technique
ISSN
1059-910X
e-ISSN
—
Svazek periodika
64
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
151-155
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—