Methodological Aspects of In Vitro Assessment of Bio-accessible Risk Element Pool in Urban Particulate Matter
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985823%3A_____%2F14%3A00434532" target="_blank" >RIV/67985823:_____/14:00434532 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41210/14:65804 RIV/60461373:22810/14:43897500
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s12011-014-0101-x" target="_blank" >http://dx.doi.org/10.1007/s12011-014-0101-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s12011-014-0101-x" target="_blank" >10.1007/s12011-014-0101-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methodological Aspects of In Vitro Assessment of Bio-accessible Risk Element Pool in Urban Particulate Matter
Popis výsledku v původním jazyce
In vitro tests simulating the elements release from inhaled urban particulate matter with artificial lung fluids and simulated gastric and pancreatic solutions were applied for an estimation of hazardous element bioaccessibility in this material. An inductively coupled plasma optical emission spectrometry (ICP-OES) and an inductively coupled plasma mass spectrometry (ICP-MS) were employed for the element determination in extracted solutions. The effect of the extraction agent used, extraction time, sample-to-extractant ratio, sample particle size and/or individual element properties was evaluated. Results of simulated in vitro tests can be applied for the reasonable estimation of bio-accessible element portions in the particulate matter as an alternative method, which, consequently, initiates further examinations including potential in vivo assessments
Název v anglickém jazyce
Methodological Aspects of In Vitro Assessment of Bio-accessible Risk Element Pool in Urban Particulate Matter
Popis výsledku anglicky
In vitro tests simulating the elements release from inhaled urban particulate matter with artificial lung fluids and simulated gastric and pancreatic solutions were applied for an estimation of hazardous element bioaccessibility in this material. An inductively coupled plasma optical emission spectrometry (ICP-OES) and an inductively coupled plasma mass spectrometry (ICP-MS) were employed for the element determination in extracted solutions. The effect of the extraction agent used, extraction time, sample-to-extractant ratio, sample particle size and/or individual element properties was evaluated. Results of simulated in vitro tests can be applied for the reasonable estimation of bio-accessible element portions in the particulate matter as an alternative method, which, consequently, initiates further examinations including potential in vivo assessments
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biological Trace Element Research
ISSN
0163-4984
e-ISSN
—
Svazek periodika
161
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
216-222
Kód UT WoS článku
000344084800009
EID výsledku v databázi Scopus
—