Enhancing electroanalytical performance of porous boron-doped diamond electrodes by increasing thickness for dopamine detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985823%3A_____%2F21%3A00549371" target="_blank" >RIV/67985823:_____/21:00549371 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378271:_____/21:00549371 RIV/00216208:11310/21:10435884 RIV/68407700:21460/21:00356794
Výsledek na webu
<a href="https://doi.org/10.1016/j.aca.2021.338949" target="_blank" >https://doi.org/10.1016/j.aca.2021.338949</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2021.338949" target="_blank" >10.1016/j.aca.2021.338949</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enhancing electroanalytical performance of porous boron-doped diamond electrodes by increasing thickness for dopamine detection
Popis výsledku v původním jazyce
This study reports on morphological, spectral, and electrochemical characterisation of 3 BDDporous electrodes of different thickness given by a number of deposited layers (2, 3 and 5), prepared using MWPECVD on SiO2 nanofiber-based scaffolds. The effect of thickness and poly-l-lysine coating on sensing properties of dopamine in a pH 7.4 phosphate buffer media was investigated. A boron doping level of ∼2 × 1021 atoms cm−3 and increased content of sp2 carbon in electrodes with more layers was evaluated by Raman spectroscopy. CV revealed reduced working potential windows (from 2.4 to 2.2 V), higher double-layer capacitance values (from 405 to 1060 μF cm−2), enhanced rates of electron transfer kinetics and larger effective surface areas (from 5.04 to 7.72 mm2), when the number of porous layers increases.
Název v anglickém jazyce
Enhancing electroanalytical performance of porous boron-doped diamond electrodes by increasing thickness for dopamine detection
Popis výsledku anglicky
This study reports on morphological, spectral, and electrochemical characterisation of 3 BDDporous electrodes of different thickness given by a number of deposited layers (2, 3 and 5), prepared using MWPECVD on SiO2 nanofiber-based scaffolds. The effect of thickness and poly-l-lysine coating on sensing properties of dopamine in a pH 7.4 phosphate buffer media was investigated. A boron doping level of ∼2 × 1021 atoms cm−3 and increased content of sp2 carbon in electrodes with more layers was evaluated by Raman spectroscopy. CV revealed reduced working potential windows (from 2.4 to 2.2 V), higher double-layer capacitance values (from 405 to 1060 μF cm−2), enhanced rates of electron transfer kinetics and larger effective surface areas (from 5.04 to 7.72 mm2), when the number of porous layers increases.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-03187S" target="_blank" >GA20-03187S: Studium elektrochemických a adsorpčních dějů na nanostrukturovaných sp2 a sp3 uhlíkových površích ve vztahu k jejich fyzikálně chemickým vlastnostem</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
1873-4324
Svazek periodika
1182
Číslo periodika v rámci svazku
Oct
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
16
Strana od-do
338949
Kód UT WoS článku
000693662300004
EID výsledku v databázi Scopus
2-s2.0-85113732581