Stopové prvky v supergenním tmelovém kalcitu: porovnání ICP-MS z roztoku a při laserové ablaci a kalibrace vzhledem k různým referenčním materiálům (SRM NIST sklo a USGS MACS karbonáty)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985831%3A_____%2F08%3A00313418" target="_blank" >RIV/67985831:_____/08:00313418 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Trace elements in landfill calcite: a comparison of solution & laser ablation ICP-MS and calibration to different standard material (SRM NIST glass and USGS MACS carbonate)
Popis výsledku v původním jazyce
In-situ trace element analytical techniques used for various landfill calcites -vs- new USGS carbonate reference materials MACS-1 and MACS-2 have been have been refined. Two different methods were used to determine selected trace elements - solution andlaser ablation ICP-MS - and the data obtained were mutualy compared. Calcites precipitating from landfill leachates are important carriers for trace elements, e.g. heavy metals and metalloids. Both the natural and experimental enrichment of landfill calcite in impurity combines the effects of their influx and calcite precipitation. Technically, when calcite is precipitating from leachate in small amounts, it is often preventing the classical solution ICP-MS analysis of trace elements. This study reportsseveral aspects but main emphasis was put on the verification of in situ trace element analysis by LA-ICP-MS.
Název v anglickém jazyce
Trace elements in landfill calcite: a comparison of solution & laser ablation ICP-MS and calibration to different standard material (SRM NIST glass and USGS MACS carbonate)
Popis výsledku anglicky
In-situ trace element analytical techniques used for various landfill calcites -vs- new USGS carbonate reference materials MACS-1 and MACS-2 have been have been refined. Two different methods were used to determine selected trace elements - solution andlaser ablation ICP-MS - and the data obtained were mutualy compared. Calcites precipitating from landfill leachates are important carriers for trace elements, e.g. heavy metals and metalloids. Both the natural and experimental enrichment of landfill calcite in impurity combines the effects of their influx and calcite precipitation. Technically, when calcite is precipitating from leachate in small amounts, it is often preventing the classical solution ICP-MS analysis of trace elements. This study reportsseveral aspects but main emphasis was put on the verification of in situ trace element analysis by LA-ICP-MS.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DB - Geologie a mineralogie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA300130702" target="_blank" >IAA300130702: Růstové rytmy jako indikátor rotace Země a změn klimatu v geologické minulosti.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Macla
ISSN
1885-7264
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
ES - Španělské království
Počet stran výsledku
2
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—