Remark on the strain based hemolysis models for viscoelastic fluids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985840%3A_____%2F25%3A00635609" target="_blank" >RIV/67985840:_____/25:00635609 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/25:00383307
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-031-86173-4_16" target="_blank" >http://dx.doi.org/10.1007/978-3-031-86173-4_16</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-031-86173-4_16" target="_blank" >10.1007/978-3-031-86173-4_16</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Remark on the strain based hemolysis models for viscoelastic fluids
Popis výsledku v původním jazyce
This paper shows how a strain based hemolysis indicator can be built from a non-linear viscoelastic model describing the rheology of blood. It is shown that the principal stretches arising from the spectrum of a left Cauchy-Green elastic stretch tensor of the fluid can be used to estimate the areal strain (relative change of a fluid parcel surface area) under the flow conditions. The high areal strain can be used as an indicator of regions where stress induced hemolysis is occurring. This approach is put in the context of a similar model based on a fluid droplet analogy. Some first numerical simulations are presented for a case of smooth axisymmetric stenosis, pointing out the critical flow regions predicted by both approaches.
Název v anglickém jazyce
Remark on the strain based hemolysis models for viscoelastic fluids
Popis výsledku anglicky
This paper shows how a strain based hemolysis indicator can be built from a non-linear viscoelastic model describing the rheology of blood. It is shown that the principal stretches arising from the spectrum of a left Cauchy-Green elastic stretch tensor of the fluid can be used to estimate the areal strain (relative change of a fluid parcel surface area) under the flow conditions. The high areal strain can be used as an indicator of regions where stress induced hemolysis is occurring. This approach is put in the context of a similar model based on a fluid droplet analogy. Some first numerical simulations are presented for a case of smooth axisymmetric stenosis, pointing out the critical flow regions predicted by both approaches.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10101 - Pure mathematics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-01591S" target="_blank" >GA22-01591S: Matematická teorie a numerická analýza rovnic vazkých newtonovských stlačitelných tekutin</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Numerical Mathematics and Advanced Applications ENUMATH 2023
ISBN
978-3-031-86172-7
ISSN
1439-7358
e-ISSN
2197-7100
Počet stran výsledku
9
Strana od-do
159-167
Název nakladatele
Springer
Místo vydání
Cham
Místo konání akce
Lisbon
Datum konání akce
4. 9. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—