Aerosol Chemical Mass Closure during the EUROTRAC-2 AEROSOL Intercomparison 2000.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F02%3A27020065" target="_blank" >RIV/67985858:_____/02:27020065 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Aerosol Chemical Mass Closure during the EUROTRAC-2 AEROSOL Intercomparison 2000.
Popis výsledku v původním jazyce
The field work for the AEROSOL Intercomparison 2000 took place from 4 to 14 April 2000 at Melpitz, Germany. One objective was to assess to which extent aerosol chemical mass closure could be obtained for the site. For this purpose, we operated four filter samplers in parallel (mostly using 12-h collections): two Gent PM 10 stacked filter unit (SFU) samplers (one with coarse and fine Nuclepore polycarbonate filters, the other with a Gelman Teflo filter as fine filter) and two single filter holders (one with PM2.5 inlet, the other with PM10 inlet) with Whatman QM-A quartz fibre filters. All samples were analysed for the particulate mass (PM) by weighing; the samples from the first SFU were analysed for 42 elements by a combination of particle-induced X-ray emission spectroscopy and instrumental neutron activation analysis, those from the other SFU for major anions and cations by ion chromatography. All quartz filters were analysed for organic carbon and elemental carbon by a thermal-opti
Název v anglickém jazyce
Aerosol Chemical Mass Closure during the EUROTRAC-2 AEROSOL Intercomparison 2000.
Popis výsledku anglicky
The field work for the AEROSOL Intercomparison 2000 took place from 4 to 14 April 2000 at Melpitz, Germany. One objective was to assess to which extent aerosol chemical mass closure could be obtained for the site. For this purpose, we operated four filter samplers in parallel (mostly using 12-h collections): two Gent PM 10 stacked filter unit (SFU) samplers (one with coarse and fine Nuclepore polycarbonate filters, the other with a Gelman Teflo filter as fine filter) and two single filter holders (one with PM2.5 inlet, the other with PM10 inlet) with Whatman QM-A quartz fibre filters. All samples were analysed for the particulate mass (PM) by weighing; the samples from the first SFU were analysed for 42 elements by a combination of particle-induced X-ray emission spectroscopy and instrumental neutron activation analysis, those from the other SFU for major anions and cations by ion chromatography. All quartz filters were analysed for organic carbon and elemental carbon by a thermal-opti
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
186
Číslo periodika v rámci svazku
N/A
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
233-237
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—