Effective Purification of Biogas by Condensing-Liquid Membrane
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F10%3A00355044" target="_blank" >RIV/67985858:_____/10:00355044 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effective Purification of Biogas by Condensing-Liquid Membrane
Popis výsledku v původním jazyce
In summary, a new method for raw biogas purification and carbon dioxide separation by a CLM was developed. The separation is based on the different solubility of components of raw biogas in a very thin, continuously refreshed water layer on/in a hydrophilic porous membrane. The permeation flux of each component of biogas depends on the feed flow rate of the gases and pressure and temperature differences between the upstream and downstream side of the CLM. The selectivity of the CLM increases with a lower feed flow rate. The molar balance based on 43 linear equations confirmed the hight potential of this method to upgrade raw biogas to natural-gas quality. The CLM can also be used under unfavorable conditions in which other polymeric membranes could becontaminated or destroyed by aggressive substances.
Název v anglickém jazyce
Effective Purification of Biogas by Condensing-Liquid Membrane
Popis výsledku anglicky
In summary, a new method for raw biogas purification and carbon dioxide separation by a CLM was developed. The separation is based on the different solubility of components of raw biogas in a very thin, continuously refreshed water layer on/in a hydrophilic porous membrane. The permeation flux of each component of biogas depends on the feed flow rate of the gases and pressure and temperature differences between the upstream and downstream side of the CLM. The selectivity of the CLM increases with a lower feed flow rate. The molar balance based on 43 linear equations confirmed the hight potential of this method to upgrade raw biogas to natural-gas quality. The CLM can also be used under unfavorable conditions in which other polymeric membranes could becontaminated or destroyed by aggressive substances.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F245" target="_blank" >FR-TI1/245: *Čištění bioplynu z čističek odpadních vod, pomocí iontových, zakotvených membrán</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Angewandte Chemie. International Edition in English
ISSN
1433-7851
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
000286573700016
EID výsledku v databázi Scopus
—