Homogenous Nucleation of Sulfuric Acid and Water at Close to Atmospherically Relevant Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F11%3A00360056" target="_blank" >RIV/67985858:_____/11:00360056 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.5194/acp-11-5277-2011" target="_blank" >http://dx.doi.org/10.5194/acp-11-5277-2011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5194/acp-11-5277-2011" target="_blank" >10.5194/acp-11-5277-2011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Homogenous Nucleation of Sulfuric Acid and Water at Close to Atmospherically Relevant Conditions
Popis výsledku v původním jazyce
In this study the homogeneous nucleation rates in the system of sulfuric acid and water were measured by using a flow tube technique. The goal was to directly compare particle formation rates obtained from atmospheric measurements with nucleation rates of freshly nucleated particles measured with particle size magnifier (PSM) which has detection efficiency of unity for particles having mobility diameter of 1.5 nm. The gas phase sulfuric acid concentration in this study was measured with the chemical ionization mass spectrometer (CIMS), commonly used in field measurements. The wall losses of sulfuric acid were estimated from measured concentration profiles along the flow tube.
Název v anglickém jazyce
Homogenous Nucleation of Sulfuric Acid and Water at Close to Atmospherically Relevant Conditions
Popis výsledku anglicky
In this study the homogeneous nucleation rates in the system of sulfuric acid and water were measured by using a flow tube technique. The goal was to directly compare particle formation rates obtained from atmospheric measurements with nucleation rates of freshly nucleated particles measured with particle size magnifier (PSM) which has detection efficiency of unity for particles having mobility diameter of 1.5 nm. The gas phase sulfuric acid concentration in this study was measured with the chemical ionization mass spectrometer (CIMS), commonly used in field measurements. The wall losses of sulfuric acid were estimated from measured concentration profiles along the flow tube.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Atmospheric Chemistry and Physics
ISSN
1680-7316
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
11
Strana od-do
5277-5287
Kód UT WoS článku
000291636400011
EID výsledku v databázi Scopus
—