Comparison of the Transport Models of a Laminar Flow Diffusion Chamber
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F13%3A00394769" target="_blank" >RIV/67985858:_____/13:00394769 - isvavai.cz</a>
Výsledek na webu
<a href="http://proceedings.aip.org/resource/2/apcpcs/1527/1?isAuthorized=no" target="_blank" >http://proceedings.aip.org/resource/2/apcpcs/1527/1?isAuthorized=no</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4803208" target="_blank" >10.1063/1.4803208</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of the Transport Models of a Laminar Flow Diffusion Chamber
Popis výsledku v původním jazyce
The aim of this work is to show how the complexity of the modeling of the transport processes affects the results of the nucleation experiments in the Laminar Flow Diffusion Chamber (LFDC). For this purpose, data measured by Hyvärinen et al. [1] were recalculated using models at different levels of complexity. We focused on the influence of hydrodynamics (Navier-Stokes equations or parabolic profile assumption) and coupled terms (Dufour effect and thermodiffusion) on the results. We found that the choice of hydrodynamic model affects both the position of nucleation maxima in the LFDC and the maximum of the nucleation rate. On the other hand, the presence of coupled terms in the model significantly affects only the peak value of the nucleation rate. Inorder to compare the results obtained by different models, we present a method quantifying relative uncertainty in the determination of the nucleation rate. The prediction of each model was compared to the full model with the Navier-Stoke
Název v anglickém jazyce
Comparison of the Transport Models of a Laminar Flow Diffusion Chamber
Popis výsledku anglicky
The aim of this work is to show how the complexity of the modeling of the transport processes affects the results of the nucleation experiments in the Laminar Flow Diffusion Chamber (LFDC). For this purpose, data measured by Hyvärinen et al. [1] were recalculated using models at different levels of complexity. We focused on the influence of hydrodynamics (Navier-Stokes equations or parabolic profile assumption) and coupled terms (Dufour effect and thermodiffusion) on the results. We found that the choice of hydrodynamic model affects both the position of nucleation maxima in the LFDC and the maximum of the nucleation rate. On the other hand, the presence of coupled terms in the model significantly affects only the peak value of the nucleation rate. Inorder to compare the results obtained by different models, we present a method quantifying relative uncertainty in the determination of the nucleation rate. The prediction of each model was compared to the full model with the Navier-Stoke
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA200760905" target="_blank" >IAA200760905: Termofyzikální vlastnosti vody v neprobádaných technicky významných oblastech</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings, Volume 1527
ISBN
978-0-7354-1152-4
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
79-82
Název nakladatele
AIP Publishing
Místo vydání
Melville, New York
Místo konání akce
Fort Collins, Colorado
Datum konání akce
23. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000319766400018