Electrodiffusion Method of Near-Wall Flow Diagnostics in Microfluidic Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F14%3A00438759" target="_blank" >RIV/67985858:_____/14:00438759 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrodiffusion Method of Near-Wall Flow Diagnostics in Microfluidic Systems
Popis výsledku v původním jazyce
A novel technique for fabrication of plastic microfluidic systems with integrated metal microelectrodes (called technique of sacrificed substrate) enables us to produce microfluidic devices with precisely shaped sensors for wall shear stress measurements. Several micrometer thick gold sensors built-in a plastic substrate exhibit good mechanical resistance and smoothness. Proper functioning of prepared chips with microsensors has been first tested in various calibration experiments (polarization curve, sensor response to polarization set-up, steady flow calibration, temperature dependence of diffusivity). Our first results obtained for separating/reattaching flow behind a backward-facing step and for gas-liquid Taylor flow in microchannels then demonstrate its applicability for the detection of near-wall flow reversal, the delimitation of flow-recirculation zones, and the determination of wall shear stress response to moving bubbles.
Název v anglickém jazyce
Electrodiffusion Method of Near-Wall Flow Diagnostics in Microfluidic Systems
Popis výsledku anglicky
A novel technique for fabrication of plastic microfluidic systems with integrated metal microelectrodes (called technique of sacrificed substrate) enables us to produce microfluidic devices with precisely shaped sensors for wall shear stress measurements. Several micrometer thick gold sensors built-in a plastic substrate exhibit good mechanical resistance and smoothness. Proper functioning of prepared chips with microsensors has been first tested in various calibration experiments (polarization curve, sensor response to polarization set-up, steady flow calibration, temperature dependence of diffusivity). Our first results obtained for separating/reattaching flow behind a backward-facing step and for gas-liquid Taylor flow in microchannels then demonstrate its applicability for the detection of near-wall flow reversal, the delimitation of flow-recirculation zones, and the determination of wall shear stress response to moving bubbles.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F12%2F0585" target="_blank" >GAP101/12/0585: Využití elektrodifúzních čidel pro studium proudění v mikrofluidních systémech</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings
ISBN
9781908549167
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
1-8
Název nakladatele
University College London
Místo vydání
London
Místo konání akce
London
Datum konání akce
7. 9. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—