Characterization of Indoor Air Quality in Different Archives – Possible Implications for Books and Manuscripts.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F17%3A00474557" target="_blank" >RIV/67985858:_____/17:00474557 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70979821:_____/17:N0000020
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.buildenv.2017.05.009" target="_blank" >http://dx.doi.org/10.1016/j.buildenv.2017.05.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.buildenv.2017.05.009" target="_blank" >10.1016/j.buildenv.2017.05.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of Indoor Air Quality in Different Archives – Possible Implications for Books and Manuscripts.
Popis výsledku v původním jazyce
Concentrations of NO2, SO2, O3, acetic and formic acids, HNO3, and NH3 were measured indoors and outdoors at five different archives. Intensive sampling was performed over a one-year period at every location using diffusive samplers in order to reveal sources of pollutants, determine the relationship between indoor and outdoor environments, and to evaluate the potential influence on archival collections. The results showed that all the observed archives, except for the depository equipped with filters for gaseous pollutants, are not suitable for the long-term storage of books and manuscripts.
Název v anglickém jazyce
Characterization of Indoor Air Quality in Different Archives – Possible Implications for Books and Manuscripts.
Popis výsledku anglicky
Concentrations of NO2, SO2, O3, acetic and formic acids, HNO3, and NH3 were measured indoors and outdoors at five different archives. Intensive sampling was performed over a one-year period at every location using diffusive samplers in order to reveal sources of pollutants, determine the relationship between indoor and outdoor environments, and to evaluate the potential influence on archival collections. The results showed that all the observed archives, except for the depository equipped with filters for gaseous pollutants, are not suitable for the long-term storage of books and manuscripts.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/DF11P01OVV020" target="_blank" >DF11P01OVV020: Metodika hodnocení vlivu kvality ovzduší na knihovní a archivní fondy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Building and Environment
ISSN
0360-1323
e-ISSN
—
Svazek periodika
120
Číslo periodika v rámci svazku
August 1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
77-84
Kód UT WoS článku
000403857500007
EID výsledku v databázi Scopus
2-s2.0-85019102919