Comparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-Line FID Detection Method.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F17%3A00475966" target="_blank" >RIV/67985858:_____/17:00475966 - isvavai.cz</a>
Výsledek na webu
<a href="http://silverstripe.fkit.hr/cabeq/assets/Uploads/03-2-2017.pdf" target="_blank" >http://silverstripe.fkit.hr/cabeq/assets/Uploads/03-2-2017.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15255/CABEQ.2016.1017" target="_blank" >10.15255/CABEQ.2016.1017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-Line FID Detection Method.
Popis výsledku v původním jazyce
This manuscript presents a novel method for the analysis of vapour permeation through polymeric membranes based on in-line analysis of the permeate with an FID detector. The hexane vapour permeation was studied for two commercially available membranes, namely low-density polyethylene (LDPE) and thin-film-composite polyamide (PA) membrane. The hexane permeation was studied at temperatures of 25–45 °C, hexane vapour activity in the range of 0.2–0.8 and trans-membrane pressures of 5–50 kPa. Two fundamentally different membranes were chosen to demonstrate the potential and sensitivity of the permeation apparatus. Upon increasing the temperature from 25 to 45 °C, the flux in LDPE was found to increase almost fourfold over the whole activity range. The nonlinear increase of the flux with activity indicates plasticization of the polymer by hexane. Contrarily, the flux in the PA membrane increases almost linearly with activity, with only a minor upward curvature. Since the PA is far away from any phase transition, it is less temperature-dependent than LDPE. The activation energy for permeation demonstrates that the temperature dependence in the LDPE membrane is dominated by changes in diffusion, whereas it is dominated by changes in solubility in the PA membrane.n
Název v anglickém jazyce
Comparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-Line FID Detection Method.
Popis výsledku anglicky
This manuscript presents a novel method for the analysis of vapour permeation through polymeric membranes based on in-line analysis of the permeate with an FID detector. The hexane vapour permeation was studied for two commercially available membranes, namely low-density polyethylene (LDPE) and thin-film-composite polyamide (PA) membrane. The hexane permeation was studied at temperatures of 25–45 °C, hexane vapour activity in the range of 0.2–0.8 and trans-membrane pressures of 5–50 kPa. Two fundamentally different membranes were chosen to demonstrate the potential and sensitivity of the permeation apparatus. Upon increasing the temperature from 25 to 45 °C, the flux in LDPE was found to increase almost fourfold over the whole activity range. The nonlinear increase of the flux with activity indicates plasticization of the polymer by hexane. Contrarily, the flux in the PA membrane increases almost linearly with activity, with only a minor upward curvature. Since the PA is far away from any phase transition, it is less temperature-dependent than LDPE. The activation energy for permeation demonstrates that the temperature dependence in the LDPE membrane is dominated by changes in diffusion, whereas it is dominated by changes in solubility in the PA membrane.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LD14094" target="_blank" >LD14094: Zakotvené iontové membrány pro selektivní dělení těkavých organických par a polutantů z odpadních plynů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical and Biochemical Engineering Quarterly
ISSN
0352-9568
e-ISSN
1846-5153
Svazek periodika
31
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
HR - Chorvatská republika
Počet stran výsledku
16
Strana od-do
145-160
Kód UT WoS článku
000405761200004
EID výsledku v databázi Scopus
2-s2.0-85023605038