Application of Water-Swollen Thin-Film Composite Membrane in Flue Gas Purification.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F19%3A00512073" target="_blank" >RIV/67985858:_____/19:00512073 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11104/0302283" target="_blank" >http://hdl.handle.net/11104/0302283</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/ceat.201800678" target="_blank" >10.1002/ceat.201800678</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Water-Swollen Thin-Film Composite Membrane in Flue Gas Purification.
Popis výsledku v původním jazyce
A water-swollen thin-film composite membrane, which was a reverse osmosis membrane with a thin polyamide layer, was used to separate a model mixture of N-2, CO2, and SO2. The polyamide swells with water, and thus, becomes more permeable to polar gases. The flue gas contains water vapor, which must be removed before it is subjected to SO2 removal. Here moisture is employed to keep the membrane swollen. Using the model mixture, the humidified feed stream is brought to the membrane, where it is cooled below the dew point, so that water condenses on the membrane to keep the polyamide swollen. The membrane showed high CO2 and SO2 permeance, but low selectivity, so it could be applied to separate these two gases from N-2, and thus, is suitable for flue gas purification.
Název v anglickém jazyce
Application of Water-Swollen Thin-Film Composite Membrane in Flue Gas Purification.
Popis výsledku anglicky
A water-swollen thin-film composite membrane, which was a reverse osmosis membrane with a thin polyamide layer, was used to separate a model mixture of N-2, CO2, and SO2. The polyamide swells with water, and thus, becomes more permeable to polar gases. The flue gas contains water vapor, which must be removed before it is subjected to SO2 removal. Here moisture is employed to keep the membrane swollen. Using the model mixture, the humidified feed stream is brought to the membrane, where it is cooled below the dew point, so that water condenses on the membrane to keep the polyamide swollen. The membrane showed high CO2 and SO2 permeance, but low selectivity, so it could be applied to separate these two gases from N-2, and thus, is suitable for flue gas purification.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA18-05484S" target="_blank" >GA18-05484S: Čištění spalin membránovými procesy</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Engineering & Technology
ISSN
0930-7516
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
1304-1309
Kód UT WoS článku
000468795600015
EID výsledku v databázi Scopus
2-s2.0-85065968381