Monitoring of the unattached fraction of radon progeny by the Kodak LR-115 Type 2, nuclear track detector.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F21%3A00541253" target="_blank" >RIV/67985858:_____/21:00541253 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11104/0319408" target="_blank" >http://hdl.handle.net/11104/0319408</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2021.165248" target="_blank" >10.1016/j.nima.2021.165248</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monitoring of the unattached fraction of radon progeny by the Kodak LR-115 Type 2, nuclear track detector.
Popis výsledku v původním jazyce
The experimental Unattached Radon Progeny Fraction Monitor (URPFM) was developed for the parallel monitoring of all radon progeny and the fraction of radon progeny in air that is attached onto aerosols. The optimum monitor arrangement includes two radon progeny sampling columns with each column incorporating a 0.8 µm membrane filter. The filter in the first sampling column collects all the ambient radon progeny that are measured by the Kodak LR-115 nuclear track detector. The second sampling column also includes a fine mesh that removes the unattached radon progeny from the sampled air and thus the track detector that is situated above the mesh measures the unattached radon progeny.nThree, five to thirteen-day long radon progeny monitoring periods were conducted inside a sealed room of a residential house and outdoors at an open cut uranium mine. The average unattached fraction of radon progeny was measured to be between 0.09 and 0.14 for the residential house, and between 0.08 and 0.10 for the open cut uranium mine.n
Název v anglickém jazyce
Monitoring of the unattached fraction of radon progeny by the Kodak LR-115 Type 2, nuclear track detector.
Popis výsledku anglicky
The experimental Unattached Radon Progeny Fraction Monitor (URPFM) was developed for the parallel monitoring of all radon progeny and the fraction of radon progeny in air that is attached onto aerosols. The optimum monitor arrangement includes two radon progeny sampling columns with each column incorporating a 0.8 µm membrane filter. The filter in the first sampling column collects all the ambient radon progeny that are measured by the Kodak LR-115 nuclear track detector. The second sampling column also includes a fine mesh that removes the unattached radon progeny from the sampled air and thus the track detector that is situated above the mesh measures the unattached radon progeny.nThree, five to thirteen-day long radon progeny monitoring periods were conducted inside a sealed room of a residential house and outdoors at an open cut uranium mine. The average unattached fraction of radon progeny was measured to be between 0.09 and 0.14 for the residential house, and between 0.08 and 0.10 for the open cut uranium mine.n
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
1872-9576
Svazek periodika
1000
Číslo periodika v rámci svazku
Jun 1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
165248
Kód UT WoS článku
000640493300013
EID výsledku v databázi Scopus
2-s2.0-85102900144