Studie elektroreologických vlastností lidské krve
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985874%3A_____%2F06%3A00053782" target="_blank" >RIV/67985874:_____/06:00053782 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Studies of electrorheological properties of blood
Popis výsledku v původním jazyce
The blood electrorheological (ER) properties indicate changes in the blood rheological behaviour due to imposition of electric field. The work identifies and quantifies ER properties of blood at different shear rates and at different local structure of the flow field. A concurrent measurement system, using a Contraves Low Shear 30 rotational rheometer was used in the study. It includes a pair of platinum electrodes in cylindrical ring zigzag shape, embedded into the wall of a resin made replica of the Couette type flow chamber of the rheometer, constructed for conductivity measurement and associated software (Data acquisition system). The relationship between the whole blood and plasma conductivity (the active main component of blood impedance) was studied in parallel with the changes in the rheological behaviour under steady and transient flow conditions. The time variation of blood conductivity at different flow regimes and the dependences of the apparent whole blood and plasma visco
Název v anglickém jazyce
Studies of electrorheological properties of blood
Popis výsledku anglicky
The blood electrorheological (ER) properties indicate changes in the blood rheological behaviour due to imposition of electric field. The work identifies and quantifies ER properties of blood at different shear rates and at different local structure of the flow field. A concurrent measurement system, using a Contraves Low Shear 30 rotational rheometer was used in the study. It includes a pair of platinum electrodes in cylindrical ring zigzag shape, embedded into the wall of a resin made replica of the Couette type flow chamber of the rheometer, constructed for conductivity measurement and associated software (Data acquisition system). The relationship between the whole blood and plasma conductivity (the active main component of blood impedance) was studied in parallel with the changes in the rheological behaviour under steady and transient flow conditions. The time variation of blood conductivity at different flow regimes and the dependences of the apparent whole blood and plasma visco
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA2060401" target="_blank" >IAA2060401: Vliv vnitřního tlaku na termomechanické vlastnosti polymerů při fyzikálním stárnutí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical Hemorheology and Microcirculation
ISSN
1386-0291
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
1-2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
19-29
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—