Evaluation of the turbulent kinetic dissipation rate in an agitated vessel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985874%3A_____%2F17%3A00466630" target="_blank" >RIV/67985874:_____/17:00466630 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/17:00313252 RIV/46747885:24620/17:00004577
Výsledek na webu
<a href="http://dx.doi.org/10.1051/epjconf/201714302062" target="_blank" >http://dx.doi.org/10.1051/epjconf/201714302062</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201714302062" target="_blank" >10.1051/epjconf/201714302062</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of the turbulent kinetic dissipation rate in an agitated vessel
Popis výsledku v původním jazyce
The design of agitated tanks depends on operating conditions and processes for that are used for. An important parameter for the scale-up modelling is the dissipation rate of the turbulent kinetic energy. The dissipation rate is commonly assumed to be a function of the impeller power input. But this approach gives no information about distribution of the dissipation rate inside the agitated volume. In this paper the distributions of the dissipation rate inside the agitated vessels are estimated by evaluations of the CFD (Computational Fluid Dynamics). The results obtained from RANS (Reynolds Averaged Navier-Stokes equations) k-epsilon turbulent model and LES (Large Eddy Simulations) with Smagorinsky SGS (Sub Grid Scale) model are compared. The agitated vessels with standard geometry equipped with four baffles and stirred by either a standard Rushton turbine or a high shear impeller were investigated. The results are compared with mean dissipation rate estimated from the total impeller power input.
Název v anglickém jazyce
Evaluation of the turbulent kinetic dissipation rate in an agitated vessel
Popis výsledku anglicky
The design of agitated tanks depends on operating conditions and processes for that are used for. An important parameter for the scale-up modelling is the dissipation rate of the turbulent kinetic energy. The dissipation rate is commonly assumed to be a function of the impeller power input. But this approach gives no information about distribution of the dissipation rate inside the agitated volume. In this paper the distributions of the dissipation rate inside the agitated vessels are estimated by evaluations of the CFD (Computational Fluid Dynamics). The results obtained from RANS (Reynolds Averaged Navier-Stokes equations) k-epsilon turbulent model and LES (Large Eddy Simulations) with Smagorinsky SGS (Sub Grid Scale) model are compared. The agitated vessels with standard geometry equipped with four baffles and stirred by either a standard Rushton turbine or a high shear impeller were investigated. The results are compared with mean dissipation rate estimated from the total impeller power input.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
EDP Sciences
Místo vydání
Les Ulis
Místo konání akce
Mariánské Lázně
Datum konání akce
15. 11. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000407743800064