Analysis and discussion of two fluid modelling of pipe flow of fully suspended slurry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985874%3A_____%2F20%3A00521317" target="_blank" >RIV/67985874:_____/20:00521317 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0032591019307429?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0032591019307429?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.powtec.2019.09.017" target="_blank" >10.1016/j.powtec.2019.09.017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis and discussion of two fluid modelling of pipe flow of fully suspended slurry
Popis výsledku v původním jazyce
Thanks to the advancements in computer power and capability of Computational Fluid Dynamics codes, the amount of research work on the numerical simulation of slurry flows in pipelines has increased exponentially in few years, opening the way to the use of this approach for engineering purposes. The Two Fluid Model (TFM), in which both phases are interpreted as interpenetrating continua and solved in the Eulerian, cell-based framework, allows the best compromise considering the engineering requirements of computational efficiency, applicability, and accuracy. However, the solution of this model is affected by several numerical and modelling factors, and, even if good agreement is achieved between simulation results and experimental measurements, it might be difficult to trust the predictions outside the validation conditions, thereby limiting the engineering potential of the two-fluid approach. The fully-suspended slurry flow in horizontal pipes was numerically simulated using the TFM recently developed by one of the authors of this paper, and the computational results were compared to experimental data reported in the literature. It has been clearly demonstrated that, even in this simple geometry, many possible sources of inaccuracy and uncertainty come into play. Whilst assessing their role, best practice guidelines and consistency checks were proposed to improve the accuracy of the estimates and increase the reliability of the TFM solution. Afterwards, pipe size-up scaling tests and a careful specification of the applicability conditions provided further confidence to the use of the TFM as a tool for engineering design.
Název v anglickém jazyce
Analysis and discussion of two fluid modelling of pipe flow of fully suspended slurry
Popis výsledku anglicky
Thanks to the advancements in computer power and capability of Computational Fluid Dynamics codes, the amount of research work on the numerical simulation of slurry flows in pipelines has increased exponentially in few years, opening the way to the use of this approach for engineering purposes. The Two Fluid Model (TFM), in which both phases are interpreted as interpenetrating continua and solved in the Eulerian, cell-based framework, allows the best compromise considering the engineering requirements of computational efficiency, applicability, and accuracy. However, the solution of this model is affected by several numerical and modelling factors, and, even if good agreement is achieved between simulation results and experimental measurements, it might be difficult to trust the predictions outside the validation conditions, thereby limiting the engineering potential of the two-fluid approach. The fully-suspended slurry flow in horizontal pipes was numerically simulated using the TFM recently developed by one of the authors of this paper, and the computational results were compared to experimental data reported in the literature. It has been clearly demonstrated that, even in this simple geometry, many possible sources of inaccuracy and uncertainty come into play. Whilst assessing their role, best practice guidelines and consistency checks were proposed to improve the accuracy of the estimates and increase the reliability of the TFM solution. Afterwards, pipe size-up scaling tests and a careful specification of the applicability conditions provided further confidence to the use of the TFM as a tool for engineering design.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Powder Technology
ISSN
0032-5910
e-ISSN
—
Svazek periodika
360
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
22
Strana od-do
747-768
Kód UT WoS článku
000506712100068
EID výsledku v databázi Scopus
2-s2.0-85075456133