Sensitivity of silica microspheres modified by xerogel layers to acetone and ethanol
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F11%3A00374695" target="_blank" >RIV/67985882:_____/11:00374695 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/11:00309461
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitivity of silica microspheres modified by xerogel layers to acetone and ethanol
Popis výsledku v původním jazyce
The paper deals with the preparation and characterization of whispering-gallery-mode silica spherical microresonators and with effects of liquid acetone, ethanol, and xerogel layers applied onto these microresonators on their resonance spectra. Microrespheres with diameters ranging from 320 to 360 mu m have been prepared by heating a tip of a silica fiber with a hydrogen-oxygen burner. The microspheres were excited by a fiber taper or a bulk prism and their resonance spectra were measured. Values of theQ factor from 10(4) to 10(6) have been determined from these spectra. In experiments, it has been found that short contact of microspheres with acetone causes a shift of resonance dips due to surface effects caused by acetone. A decrease of the Q factorhas been observed with a microresonator onto which a xerogel silica layer was applied by the sol-gel method. A very high decrease of the Q factor has been observed when the silica microresonator was brought in contact with liquid ethanol
Název v anglickém jazyce
Sensitivity of silica microspheres modified by xerogel layers to acetone and ethanol
Popis výsledku anglicky
The paper deals with the preparation and characterization of whispering-gallery-mode silica spherical microresonators and with effects of liquid acetone, ethanol, and xerogel layers applied onto these microresonators on their resonance spectra. Microrespheres with diameters ranging from 320 to 360 mu m have been prepared by heating a tip of a silica fiber with a hydrogen-oxygen burner. The microspheres were excited by a fiber taper or a bulk prism and their resonance spectra were measured. Values of theQ factor from 10(4) to 10(6) have been determined from these spectra. In experiments, it has been found that short contact of microspheres with acetone causes a shift of resonance dips due to surface effects caused by acetone. A decrease of the Q factorhas been observed with a microresonator onto which a xerogel silica layer was applied by the sol-gel method. A very high decrease of the Q factor has been observed when the silica microresonator was brought in contact with liquid ethanol
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F1763" target="_blank" >GA102/09/1763: Návrh, příprava a charakterizace nových typů optických mikrorezonátorů pro chemickou detekci</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Optical Sensors 2011 and Photonic Crystal Fibers V (Proceedings of SPIE Vol. 8073)
ISBN
978-0-8194-8663-9
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
"80730X1"-"80730X11"
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Praha
Datum konání akce
18. 4. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000293740400020