Electrochemical surface plasmon resonance biosensor for study of DNA desorption and hybridization
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F13%3A00396553" target="_blank" >RIV/67985882:_____/13:00396553 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2018462" target="_blank" >http://dx.doi.org/10.1117/12.2018462</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2018462" target="_blank" >10.1117/12.2018462</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical surface plasmon resonance biosensor for study of DNA desorption and hybridization
Popis výsledku v původním jazyce
We report a system, which combines electrochemical and surface plasmon resonance (SPR) techniques on the same sensing chip. Each channel of a four-channel laboratory SPR sensor is supplemented with two planar gold electrodes (the reference and the counter electrodes), whereas the gold layer of SPR chip is used as the working electrode. A custom electronics enables to set an arbitrary potential between the reference and working electrodes and to measure the current flow between the counter and the working electrodes. Information from standard electrochemical techniques, i.e. cyclovoltammetry and chronoamperometry can be acquired with the system while simultaneously monitoring the shift in the surface plasmon resonance. The electrochemical SPR biosensorwas used to study desorption of thiolated DNA probes with a negative potential. By comparing the acquired electrochemical and SPR signals, we show that DNA probes as well as a monolayer of alkanethiols can be desorbed by applying negative
Název v anglickém jazyce
Electrochemical surface plasmon resonance biosensor for study of DNA desorption and hybridization
Popis výsledku anglicky
We report a system, which combines electrochemical and surface plasmon resonance (SPR) techniques on the same sensing chip. Each channel of a four-channel laboratory SPR sensor is supplemented with two planar gold electrodes (the reference and the counter electrodes), whereas the gold layer of SPR chip is used as the working electrode. A custom electronics enables to set an arbitrary potential between the reference and working electrodes and to measure the current flow between the counter and the working electrodes. Information from standard electrochemical techniques, i.e. cyclovoltammetry and chronoamperometry can be acquired with the system while simultaneously monitoring the shift in the surface plasmon resonance. The electrochemical SPR biosensorwas used to study desorption of thiolated DNA probes with a negative potential. By comparing the acquired electrochemical and SPR signals, we show that DNA probes as well as a monolayer of alkanethiols can be desorbed by applying negative
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LH11102" target="_blank" >LH11102: Nanoplasmonické materiály vytvářené pomocí samoorganizačních procesů a jejich využití v senzorech</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
OPTICAL SENSORS 2013
ISBN
978-0-8194-9576-1
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
BELLINGHAM
Místo konání akce
Praha
Datum konání akce
15. 4. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000323326200012