Surface-plasmon resonance (SPR) sensors represent a formidable technology for molecular biology and bioanalytics applications. Here, we devise a new interrogation architecture that transforms a standard SPR chip into an optical-heterodyne clock detector comparable with the best SPR instruments. The key ingredients are (i) the conversion of refractive-index changes on the SPR chip into frequency shifts of an oscillatory electronic signal (ii) a differential probe & reference optical-cavity scheme that cancels out most source/detector noise contributions. A rigorous characterization of the sensor performance with the integration time demonstrates a refractive-index resolution on the 10(-8)-RIU level over a 1-s timescale using a bare, unstabilized SPR element. A bio-sensing test with a functionalized surface interfaced with a microfluidic flow-cell is carried out, showing detection of streptavidin via covalent bond down to concentrations of 90 fg/mm(2)
Název v anglickém jazyce
Surface-plasmon optical-heterodyne clock biosensor
Popis výsledku anglicky
Surface-plasmon resonance (SPR) sensors represent a formidable technology for molecular biology and bioanalytics applications. Here, we devise a new interrogation architecture that transforms a standard SPR chip into an optical-heterodyne clock detector comparable with the best SPR instruments. The key ingredients are (i) the conversion of refractive-index changes on the SPR chip into frequency shifts of an oscillatory electronic signal (ii) a differential probe & reference optical-cavity scheme that cancels out most source/detector noise contributions. A rigorous characterization of the sensor performance with the integration time demonstrates a refractive-index resolution on the 10(-8)-RIU level over a 1-s timescale using a bare, unstabilized SPR element. A bio-sensing test with a functionalized surface interfaced with a microfluidic flow-cell is carried out, showing detection of streptavidin via covalent bond down to concentrations of 90 fg/mm(2)
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP205%2F12%2FG118" target="_blank" >GBP205/12/G118: Nanobiofotonika pro medicínu budoucnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators B - Chemical
ISSN
0925-4005
e-ISSN
—
Svazek periodika
273
Číslo periodika v rámci svazku
10 November
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
336-341
Kód UT WoS článku
000441519000043
EID výsledku v databázi Scopus
2-s2.0-85048716871