Micro-CT in tissue engineering scaffolds designed for bone regeneration: Principles and applications
Popis výsledku
Identifikátory výsledku
Kód výsledku v IS VaVaI
Nalezeny alternativní kódy
RIV/68407700:21220/18:00329407
Výsledek na webu
DOI - Digital Object Identifier
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Micro-CT in tissue engineering scaffolds designed for bone regeneration: Principles and applications
Popis výsledku v původním jazyce
Micro-CT (micro-computed tomography) is a modern preclinical imaging method allowing non-destructive visualizations and structure analysis yielding at a resolution of a few micrometres. Tissue engineering scaffolds are a promising treatment for bone defects. Micro-CT application for the evaluation of tissue engineering scaffolds for bone surgery and traumatology application is increasing, which comprises in vitro, in vivo and ex vivo studies. Micro-CT itself is not able to replace conventional approaches completely, such as scanning electron microscopy (SEM) or histological examination, but it may offer important benefits regarding non-destructive approach, direct 3D model structure analysis, and visualization and time efficacy. The overview presented herein focuses on a micro-CT application in the field of tissue engineering scaffolds aimed at bone regeneration.
Název v anglickém jazyce
Micro-CT in tissue engineering scaffolds designed for bone regeneration: Principles and applications
Popis výsledku anglicky
Micro-CT (micro-computed tomography) is a modern preclinical imaging method allowing non-destructive visualizations and structure analysis yielding at a resolution of a few micrometres. Tissue engineering scaffolds are a promising treatment for bone defects. Micro-CT application for the evaluation of tissue engineering scaffolds for bone surgery and traumatology application is increasing, which comprises in vitro, in vivo and ex vivo studies. Micro-CT itself is not able to replace conventional approaches completely, such as scanning electron microscopy (SEM) or histological examination, but it may offer important benefits regarding non-destructive approach, direct 3D model structure analysis, and visualization and time efficacy. The overview presented herein focuses on a micro-CT application in the field of tissue engineering scaffolds aimed at bone regeneration.
Klasifikace
Druh
Jimp - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30106 - Anatomy and morphology (plant science to be 1.6)
Návaznosti výsledku
Projekt
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ceramics - Silikáty
ISSN
0862-5468
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
194-199
Kód UT WoS článku
000433644200011
EID výsledku v databázi Scopus
2-s2.0-85051957231
Základní informace
Druh výsledku
Jimp - Článek v periodiku v databázi Web of Science
OECD FORD
Anatomy and morphology (plant science to be 1.6)
Rok uplatnění
2018