Microcomputed tomographic, biomechanical and histological analyses of lumbar interbody fusion with iliac crest bone graft in a pig model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985891%3A_____%2F21%3A00542711" target="_blank" >RIV/67985891:_____/21:00542711 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/21:00357107 RIV/65269705:_____/21:00074474 RIV/00216305:26620/21:PU142047 RIV/00216224:14110/21:00122157
Výsledek na webu
<a href="https://actavet.vfu.cz/90/1/0069/" target="_blank" >https://actavet.vfu.cz/90/1/0069/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2754/avb202190010069" target="_blank" >10.2754/avb202190010069</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Microcomputed tomographic, biomechanical and histological analyses of lumbar interbody fusion with iliac crest bone graft in a pig model
Popis výsledku v původním jazyce
The main goal of this study was to assess the progress of vertebral stability after lumbar interbody fusion related to microcomputed tomography (micro CT), biomechanical analysis, and histological assessment towards spine fusion. Twelve male pigs were used, each underwent L2-3 discectomy and implantation of an iliac crest bone graft in two groups, six spines were harvested eight weeks (A1) and six spines 16 weeks (A2) after surgery (7 native spines for biomechanical analysis). The CT was performed by GE phoenix datos|x 2.0 with a sample drift correction. The samples were divided according to fusion quality. Biomechanical evaluation was carried out on the MTS Mini Bionix testing system. In the nondestructive mode, three cycles of pure bending moments were applied (5 Nm load limit) at a rate of 20 °/min in flexion (+40 °) and extension (-40 °). Two representative histological sections from four samples were obtained (A1, n = 2, A2, n = 2), areas of mature bone were quantified. In micro CT, better results were achieved in group A2 (not significant). Eight weeks after the operation, flexural stiffness decreased to 48% of its initial value for native cadavers (P < 0.05), after 16 weeks it was comparable to native cadavers, demonstrating the suitability of the implanted graft (P < 0.05). The newly formed bone tissue occupied an average area of 94.205 mm (A1) and 26.240 mm (A2). It was confirmed that micro CT, biomechanical analysis, and histological assessment are technically feasible and suitable for the evaluation of results of other methods of large bone defect treatment. 2 2
Název v anglickém jazyce
Microcomputed tomographic, biomechanical and histological analyses of lumbar interbody fusion with iliac crest bone graft in a pig model
Popis výsledku anglicky
The main goal of this study was to assess the progress of vertebral stability after lumbar interbody fusion related to microcomputed tomography (micro CT), biomechanical analysis, and histological assessment towards spine fusion. Twelve male pigs were used, each underwent L2-3 discectomy and implantation of an iliac crest bone graft in two groups, six spines were harvested eight weeks (A1) and six spines 16 weeks (A2) after surgery (7 native spines for biomechanical analysis). The CT was performed by GE phoenix datos|x 2.0 with a sample drift correction. The samples were divided according to fusion quality. Biomechanical evaluation was carried out on the MTS Mini Bionix testing system. In the nondestructive mode, three cycles of pure bending moments were applied (5 Nm load limit) at a rate of 20 °/min in flexion (+40 °) and extension (-40 °). Two representative histological sections from four samples were obtained (A1, n = 2, A2, n = 2), areas of mature bone were quantified. In micro CT, better results were achieved in group A2 (not significant). Eight weeks after the operation, flexural stiffness decreased to 48% of its initial value for native cadavers (P < 0.05), after 16 weeks it was comparable to native cadavers, demonstrating the suitability of the implanted graft (P < 0.05). The newly formed bone tissue occupied an average area of 94.205 mm (A1) and 26.240 mm (A2). It was confirmed that micro CT, biomechanical analysis, and histological assessment are technically feasible and suitable for the evaluation of results of other methods of large bone defect treatment. 2 2
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-31276A" target="_blank" >NV17-31276A: Všestranné preklinické zhodnocení laterální lumbální intervertebrální dézy hybridním biodegradabilním nanokompozitním porézním implantátem.</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta veterinaria Brno
ISSN
0001-7213
e-ISSN
1801-7576
Svazek periodika
90
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
69-75
Kód UT WoS článku
000654628800009
EID výsledku v databázi Scopus
2-s2.0-85104823198