Evaluation of micropollutant removal from artificially recharged water using activated carbon
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985891%3A_____%2F25%3A00636007" target="_blank" >RIV/67985891:_____/25:00636007 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22320/25:43932742
Výsledek na webu
<a href="https://doi.org/" target="_blank" >https://doi.org/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jhazmat.2025.138504" target="_blank" >10.1016/j.jhazmat.2025.138504</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of micropollutant removal from artificially recharged water using activated carbon
Popis výsledku v původním jazyce
Pilot scale micropollutant removal onto three types of granular activated carbon was tested over a period of 25 months. The columns were operated in a mode as similar as possible to the functioning of the main waterworks with the emphasis on minimizing the washing of the activated carbon layers. Sampling was performed monthly and a total of 222 micropollutants were evaluated. The columns were located at a waterworks in central Bohemia (Czech Republic). Real influent water from the river Jizera after artificial recharge and sand filtration was used. The aim of this study was to verify whether the process of micropollutant removal was suitable under the operating conditions at the waterworks. Clear seasonal patterns of micropollutant concentrations in the influent were detected. All three columns were able to effectively remove or substantially decrease the concentration of most micropollutants. The best performance was shown for the activated carbon Aquasorb 5005, which had the highest surface area and a well developed porous structure with the highest proportion of mesopores. The data were evaluated in order to identify micropollutant parameters important for their removal, and the pH dependent octanol/water partition coefficient was identified as the key parameter. Other important parameters were charge and polar surface area of the micropollutant molecules.
Název v anglickém jazyce
Evaluation of micropollutant removal from artificially recharged water using activated carbon
Popis výsledku anglicky
Pilot scale micropollutant removal onto three types of granular activated carbon was tested over a period of 25 months. The columns were operated in a mode as similar as possible to the functioning of the main waterworks with the emphasis on minimizing the washing of the activated carbon layers. Sampling was performed monthly and a total of 222 micropollutants were evaluated. The columns were located at a waterworks in central Bohemia (Czech Republic). Real influent water from the river Jizera after artificial recharge and sand filtration was used. The aim of this study was to verify whether the process of micropollutant removal was suitable under the operating conditions at the waterworks. Clear seasonal patterns of micropollutant concentrations in the influent were detected. All three columns were able to effectively remove or substantially decrease the concentration of most micropollutants. The best performance was shown for the activated carbon Aquasorb 5005, which had the highest surface area and a well developed porous structure with the highest proportion of mesopores. The data were evaluated in order to identify micropollutant parameters important for their removal, and the pH dependent octanol/water partition coefficient was identified as the key parameter. Other important parameters were charge and polar surface area of the micropollutant molecules.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10503 - Water resources
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Hazardous Materials
ISSN
0304-3894
e-ISSN
1873-3336
Svazek periodika
494
Číslo periodika v rámci svazku
August
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
138504
Kód UT WoS článku
001492087300005
EID výsledku v databázi Scopus
2-s2.0-105004872160