Oral Appliance Effectiveness and Patient Satisfaction with Obstructive Sleep Apnea Treatment in Adults
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985904%3A_____%2F19%3A00503754" target="_blank" >RIV/67985904:_____/19:00503754 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27120/19:10243707 RIV/61988987:17110/19:A2102749
Výsledek na webu
<a href="http://apps.webofknowledge.com/InboundService.do?customersID=Alerting&mode=FullRecord&IsProductCode=Yes&product=WOS&Init=Yes&Func=Frame&DestFail=http%3A%2F%2Fwww.webofknowledge.com&action=retrieve&SrcApp=Alerting&SrcAuth=Alerting&SID=E2rSh5PC8lxWHpWuXLT&UT=WOS%3A000456123000001" target="_blank" >http://apps.webofknowledge.com/InboundService.do?customersID=Alerting&mode=FullRecord&IsProductCode=Yes&product=WOS&Init=Yes&Func=Frame&DestFail=http%3A%2F%2Fwww.webofknowledge.com&action=retrieve&SrcApp=Alerting&SrcAuth=Alerting&SID=E2rSh5PC8lxWHpWuXLT&UT=WOS%3A000456123000001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.12659/MSM.911242" target="_blank" >10.12659/MSM.911242</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Oral Appliance Effectiveness and Patient Satisfaction with Obstructive Sleep Apnea Treatment in Adults
Popis výsledku v původním jazyce
Background: Indication of oral appliances for the treatment of an obstructive sleep apnea (OSA) includes both patients with primary snoring and mild OSA, as well as patients with moderate to severe OSA who refuse other treatment or in whom such treatment failed. The aim of this study was to verify the effectiveness of current OSA treatment by objective measurements, and to assess by means of a questionnaire patients' satisfaction with oral appliances manufactured in our laboratory. nMaterial/Methods: The study enrolled 58 adult patients (40 men, 18 women) with mean age of 50.5 years, most were overweight or had class I obesity, mean baseline apnea-hypopnea index (AHI) value prior to the beginning of treatment was 31.3, range 0.6-71. nResults: Average AHI reduction in the entire group was 10.4, 31% of patients experienced AHI reduction by at least 50%. Significant AHI reduction was proven when using the appliance. Appliances affect the reduction of AHI and patients tolerate the appliances well. nConclusions: Oral appliances complement positive-pressure treatment and do not interfere with it in any way. Craniometric parameters seem to be applicable as predictors of success or failure of appliance treatment.
Název v anglickém jazyce
Oral Appliance Effectiveness and Patient Satisfaction with Obstructive Sleep Apnea Treatment in Adults
Popis výsledku anglicky
Background: Indication of oral appliances for the treatment of an obstructive sleep apnea (OSA) includes both patients with primary snoring and mild OSA, as well as patients with moderate to severe OSA who refuse other treatment or in whom such treatment failed. The aim of this study was to verify the effectiveness of current OSA treatment by objective measurements, and to assess by means of a questionnaire patients' satisfaction with oral appliances manufactured in our laboratory. nMaterial/Methods: The study enrolled 58 adult patients (40 men, 18 women) with mean age of 50.5 years, most were overweight or had class I obesity, mean baseline apnea-hypopnea index (AHI) value prior to the beginning of treatment was 31.3, range 0.6-71. nResults: Average AHI reduction in the entire group was 10.4, 31% of patients experienced AHI reduction by at least 50%. Significant AHI reduction was proven when using the appliance. Appliances affect the reduction of AHI and patients tolerate the appliances well. nConclusions: Oral appliances complement positive-pressure treatment and do not interfere with it in any way. Craniometric parameters seem to be applicable as predictors of success or failure of appliance treatment.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medical Science Monitor
ISSN
1643-3750
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
JAN 18
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
516-524
Kód UT WoS článku
000456123000001
EID výsledku v databázi Scopus
2-s2.0-85060169575