Popis výsledku v původním jazyce
A cathodic stripping transfer voltammetric procedure for trace determination of DNA and its components is described. The method is based on the DNA acid hydrolysis with subsequent electrochemical determination of released purine bases. In the first step,DNA is hydrolyzed for 30 min in 0.5 M perchloric acid at 75 degreesC. The electrochemical step involves generation of Cu(I)-purine base complex on a mercury electrode surface, transfer of electrode with accumulated complex into supporting electrolyte where voltammetric measurement is performed. Analysis is carried out in 14-mul drop volume (two-electrode connection) or in 30-mul drop (three-electrode connection) on a platinum plate, which is used as a counter electrode. Blank electrolyte contains 0.05M borate buffer, pH 9.2 with 6.3 muM Cu(II). We could observe voltammetric signal at hydrolyzed nucleosides, nucleotides, ODN, and DNA containing purine bases.
Název v anglickém jazyce
Microanalysis of DNA by stripping transfer voltammetry
Popis výsledku anglicky
A cathodic stripping transfer voltammetric procedure for trace determination of DNA and its components is described. The method is based on the DNA acid hydrolysis with subsequent electrochemical determination of released purine bases. In the first step,DNA is hydrolyzed for 30 min in 0.5 M perchloric acid at 75 degreesC. The electrochemical step involves generation of Cu(I)-purine base complex on a mercury electrode surface, transfer of electrode with accumulated complex into supporting electrolyte where voltammetric measurement is performed. Analysis is carried out in 14-mul drop volume (two-electrode connection) or in 30-mul drop (three-electrode connection) on a platinum plate, which is used as a counter electrode. Blank electrolyte contains 0.05M borate buffer, pH 9.2 with 6.3 muM Cu(II). We could observe voltammetric signal at hydrolyzed nucleosides, nucleotides, ODN, and DNA containing purine bases.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Bioelectrochemistry
ISSN
1567-5394
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
1-2
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
249-252
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—