Rtuťové elektrody v elektrochemii nukleových kyselin: citlivé analytické nástroje a sondy struktury DNA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081707%3A_____%2F04%3A00108405" target="_blank" >RIV/68081707:_____/04:00108405 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mercury electrodes in nucleic acid electrochemistry: sensitive analytical tools and probes of DNA structure. A review
Popis výsledku v původním jazyce
At the mercury electrodes, nucleic acids yield faradaic signals (due to redox processes involving adenine, cytosine and guanine residues), and tensammetric signals (due to adsorption/desorption of the polynucleotide chains at the electrode surface). Someof these signals are highly sensitive to DNA structure, providing information about conformation changes of the DNA double helix, formation of DNA strand breaks or covalent or non-covalent DNA interactions with small molecules. Measurements at the mercury electrodes allow determination of small quantities of unmodified or electrochemically labeled nucleic acids. DNA-modified mercury electrodes have been used as biodetectors for DNA damaging agents. Mercury film and solid amalgam electrodes possess similar features in the nucleic acid analysis as the mercury drop one.
Název v anglickém jazyce
Mercury electrodes in nucleic acid electrochemistry: sensitive analytical tools and probes of DNA structure. A review
Popis výsledku anglicky
At the mercury electrodes, nucleic acids yield faradaic signals (due to redox processes involving adenine, cytosine and guanine residues), and tensammetric signals (due to adsorption/desorption of the polynucleotide chains at the electrode surface). Someof these signals are highly sensitive to DNA structure, providing information about conformation changes of the DNA double helix, formation of DNA strand breaks or covalent or non-covalent DNA interactions with small molecules. Measurements at the mercury electrodes allow determination of small quantities of unmodified or electrochemically labeled nucleic acids. DNA-modified mercury electrodes have been used as biodetectors for DNA damaging agents. Mercury film and solid amalgam electrodes possess similar features in the nucleic acid analysis as the mercury drop one.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communications
ISSN
0010-0765
e-ISSN
—
Svazek periodika
69
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
33
Strana od-do
715-747
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—