Indirect photometric detection of boron cluster anions electrophoretically separated in methanol
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081707%3A_____%2F14%3A00428340" target="_blank" >RIV/68081707:_____/14:00428340 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2014.02.060" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2014.02.060</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2014.02.060" target="_blank" >10.1016/j.chroma.2014.02.060</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Indirect photometric detection of boron cluster anions electrophoretically separated in methanol
Popis výsledku v původním jazyce
3,5-Dinitrobenzoate and picrate are light absorbing anions pertinent to indirect photometric detection of boron cluster anions in buffered methanolic background electrolytes (BGEs). Tris(hydroxymethyl)aminomethane and morpholine have been used as buffering bases, which eliminated baseline steps, and minimized the baseline noise. In methanolic BGEs, mobilities of boron cluster anions depend on both ionic constituents of the BGE buffer. This dependence can be explained by ion pair interaction of detectedanions with BGE cations, which are not bonded into ion pairs with the BGE anions. The former ion pair interaction decreases sensitivity of the indirect photometric detection. (C) 2014 Elsevier B.V. All rights reserved.
Název v anglickém jazyce
Indirect photometric detection of boron cluster anions electrophoretically separated in methanol
Popis výsledku anglicky
3,5-Dinitrobenzoate and picrate are light absorbing anions pertinent to indirect photometric detection of boron cluster anions in buffered methanolic background electrolytes (BGEs). Tris(hydroxymethyl)aminomethane and morpholine have been used as buffering bases, which eliminated baseline steps, and minimized the baseline noise. In methanolic BGEs, mobilities of boron cluster anions depend on both ionic constituents of the BGE buffer. This dependence can be explained by ion pair interaction of detectedanions with BGE cations, which are not bonded into ion pairs with the BGE anions. The former ion pair interaction decreases sensitivity of the indirect photometric detection. (C) 2014 Elsevier B.V. All rights reserved.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1338
Číslo periodika v rámci svazku
APR 2014
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
174-183
Kód UT WoS článku
000334137200020
EID výsledku v databázi Scopus
—