A study od sample mineralization methods for arsenic analysis of blood and urine by hydride generation and graphite furnace atomic absorption spectrometry.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F03%3A25033019" target="_blank" >RIV/68081715:_____/03:25033019 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A study od sample mineralization methods for arsenic analysis of blood and urine by hydride generation and graphite furnace atomic absorption spectrometry.
Popis výsledku v původním jazyce
Mineralization procedures for blood and urine suitable for the determination of arsenic by hydride generation AAS (HG AAS) are studied on model samples, containing arsenic species (As(III), As(V), DMA, MMA, AsB, AsC). Results are utilized in biological monitoring investigations. Two preparation procedures for urine give arsenic recoveries close to 100 by HG AAS: a) dry ashing at 420C with magnesium nitrite and b) microwave oven decomposition with ammonium persulfate. For blood samples, arsenic recoveries by HG AAS near 100 is found using dry ashing , wet digestion in microwave oven gives recoveries very near 100 for As-inorg. and MMA only, for other species the recovery was less than 20 in spiked blood samples.
Název v anglickém jazyce
A study od sample mineralization methods for arsenic analysis of blood and urine by hydride generation and graphite furnace atomic absorption spectrometry.
Popis výsledku anglicky
Mineralization procedures for blood and urine suitable for the determination of arsenic by hydride generation AAS (HG AAS) are studied on model samples, containing arsenic species (As(III), As(V), DMA, MMA, AsB, AsC). Results are utilized in biological monitoring investigations. Two preparation procedures for urine give arsenic recoveries close to 100 by HG AAS: a) dry ashing at 420C with magnesium nitrite and b) microwave oven decomposition with ammonium persulfate. For blood samples, arsenic recoveries by HG AAS near 100 is found using dry ashing , wet digestion in microwave oven gives recoveries very near 100 for As-inorg. and MMA only, for other species the recovery was less than 20 in spiked blood samples.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IZ3980" target="_blank" >IZ3980: Metodická studie stanovení arzenu v tělních tekutinách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Chemistry
ISSN
1644-3624
e-ISSN
—
Svazek periodika
1
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
BE - Belgické království
Počet stran výsledku
13
Strana od-do
108-120
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—