Isotachophoretic determination of ketone bodies and lactate in cattle serum
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F14%3A00506796" target="_blank" >RIV/68081715:_____/14:00506796 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62157124:16270/14:43873203
Výsledek na webu
<a href="http://www.ce-ce.org/user_uploads/history/CECE2014_Brno/CECE_2014_proceedings_full.pdf" target="_blank" >http://www.ce-ce.org/user_uploads/history/CECE2014_Brno/CECE_2014_proceedings_full.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Isotachophoretic determination of ketone bodies and lactate in cattle serum
Popis výsledku v původním jazyce
The aim of the work was the optimization of isotachophoretic determination of lactate and ketone bodies (beta-hydroxybutyrate and acetoacetate) for veterinary medicine. The measurement of these metabolites is very important for the evaluation of metabolic diseases of cattle. The complete separation of these three analytes together with other possible blood components was achieved using 10 mmol/l hydrochloric acid with beta-alanine as a leading electrolyte at pH = 3.15 and 10 mmol/l sodium propionate as a terminating electrolyte. Limits of detection determined from the standard mixture for acetoacetate, lactate and beta-hydroxybutyrate were 3.75 mu mol/l, 3.96 mu mol/l and 7.46 mu mol/l, respectively.
Název v anglickém jazyce
Isotachophoretic determination of ketone bodies and lactate in cattle serum
Popis výsledku anglicky
The aim of the work was the optimization of isotachophoretic determination of lactate and ketone bodies (beta-hydroxybutyrate and acetoacetate) for veterinary medicine. The measurement of these metabolites is very important for the evaluation of metabolic diseases of cattle. The complete separation of these three analytes together with other possible blood components was achieved using 10 mmol/l hydrochloric acid with beta-alanine as a leading electrolyte at pH = 3.15 and 10 mmol/l sodium propionate as a terminating electrolyte. Limits of detection determined from the standard mixture for acetoacetate, lactate and beta-hydroxybutyrate were 3.75 mu mol/l, 3.96 mu mol/l and 7.46 mu mol/l, respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2014. 11th International Interdisciplinary Meeting on Bioanalysis
ISBN
978-80-904959-2-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
466-469
Název nakladatele
Institute of Analytical Chemistry AS CR
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
20. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000354547400150