Considerations on electrolysis in electromembrane extraction of basic drugs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F15%3A00448871" target="_blank" >RIV/68081715:_____/15:00448871 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.ce-ce.org/CECE2015/CECE%202015%20proceedings_full.pdf" target="_blank" >http://www.ce-ce.org/CECE2015/CECE%202015%20proceedings_full.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Considerations on electrolysis in electromembrane extraction of basic drugs
Popis výsledku v původním jazyce
Electrolysis may significantly affect composition and pH values of non-optimized acceptor solutions and have fatal consequences on quantitative EME results for weak and medium strong analytes. Acceptor solutions consisting of high concentrations of weakacids have therefore been proposed as suitable operational solutions for electromembrane extraction (EME) of selected basic drugs. 500 mM formic acid efficiently eliminated the electrolytically produced OH? ions, offered constant pH and thus long-term EME performance and was easily compatible with subsequent analytical methods. Maximum EME recoveries ranged from 66 to 89% and were constant between 40 and 80 min of EME and no back-extraction of the analytes into donor solutions was observed.
Název v anglickém jazyce
Considerations on electrolysis in electromembrane extraction of basic drugs
Popis výsledku anglicky
Electrolysis may significantly affect composition and pH values of non-optimized acceptor solutions and have fatal consequences on quantitative EME results for weak and medium strong analytes. Acceptor solutions consisting of high concentrations of weakacids have therefore been proposed as suitable operational solutions for electromembrane extraction (EME) of selected basic drugs. 500 mM formic acid efficiently eliminated the electrolytically produced OH? ions, offered constant pH and thus long-term EME performance and was easily compatible with subsequent analytical methods. Maximum EME recoveries ranged from 66 to 89% and were constant between 40 and 80 min of EME and no back-extraction of the analytes into donor solutions was observed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-05762S" target="_blank" >GA13-05762S: Teorie, metodologie a vývoj progresivních chemických metod pro analýzu stopových složek a složitých vzorků kapilární elektroforézou.</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2015. 12th International Interdisciplinary Meeting on Bioanalysis
ISBN
978-80-904959-3-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
198-201
Název nakladatele
Ústav analytické chemie AV ČR, v. v. i
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
21. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—