A novel nanospray liquid junction interface for versatile CE-MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F16%3A00467686" target="_blank" >RIV/68081715:_____/16:00467686 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A novel nanospray liquid junction interface for versatile CE-MS
Popis výsledku v původním jazyce
In this work we present a new polyimide-based liquid junction nanospray interface, combining the advantages of sheath flow and sheathless designs. The liquid junction interface was prepared as a hybrid microfabricated plastic liquid junction sprayer allowing to perform analysis in standard (30-100 micro m ID) separation capillaries. The interface incorporates a self-aligning port for coupling of the separation capillary as well as ports for automated flushing of both the liquid junction and the separation capillary. The interface permits performing CE both with and without electroosmotic flow. The use of large bore capillaries allows injection and preconcentration of larger sample volumes, favoring detection sensitivity. Different compositions of the spray liquid and BGE can be used when needed.
Název v anglickém jazyce
A novel nanospray liquid junction interface for versatile CE-MS
Popis výsledku anglicky
In this work we present a new polyimide-based liquid junction nanospray interface, combining the advantages of sheath flow and sheathless designs. The liquid junction interface was prepared as a hybrid microfabricated plastic liquid junction sprayer allowing to perform analysis in standard (30-100 micro m ID) separation capillaries. The interface incorporates a self-aligning port for coupling of the separation capillary as well as ports for automated flushing of both the liquid junction and the separation capillary. The interface permits performing CE both with and without electroosmotic flow. The use of large bore capillaries allows injection and preconcentration of larger sample volumes, favoring detection sensitivity. Different compositions of the spray liquid and BGE can be used when needed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2016. 13th International Interdisciplinary Meeting on Bioanalysis
ISBN
978-80-904959-4-4
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
28-28
Název nakladatele
Ústav analytické chemie AV ČR, v. v. i.
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
17. 10. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—