Immobilization of a phosphonium ionic liquid on a silica monolith forhydrophilic interaction chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F18%3A00490130" target="_blank" >RIV/68081715:_____/18:00490130 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2018.04.012" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2018.04.012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2018.04.012" target="_blank" >10.1016/j.chroma.2018.04.012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Immobilization of a phosphonium ionic liquid on a silica monolith forhydrophilic interaction chromatography
Popis výsledku v původním jazyce
A methodology for preparing phosphonium-based ionic liquid modified silica-based monolithic cap-illary columns is presented. The silica monolithic columns with dimensions of 150 × 0.1 mm weremodified by a phosphonium-based ionic liquid (trioctyl(3/4-vinylbenzyl)phosphonium chloride) via3-(trimethoxysilyl)propyl methacrylate. The prepared columns were evaluated under hydrophilic inter-action liquid chromatography separation conditions, employing a sample mixture containing purine andpyrimidine bases and nucleosides. Detection was made by UV. The high efficiency of the original silicamonolith was preserved even after modification, and it reached values in the range of 98,000–174,000theoretical plates/m. The effects of the concentration of acetonitrile in the mobile phase, the presence ofadditives in the mobile phase, such as, acetic acid or ammonium acetate, and the pH of the mobile phaseon the separation of some selected analytes were investigated. The prepared columns showed differentseparation selectivity compared to silica, phenyl and sulfobetaine stationary phases.
Název v anglickém jazyce
Immobilization of a phosphonium ionic liquid on a silica monolith forhydrophilic interaction chromatography
Popis výsledku anglicky
A methodology for preparing phosphonium-based ionic liquid modified silica-based monolithic cap-illary columns is presented. The silica monolithic columns with dimensions of 150 × 0.1 mm weremodified by a phosphonium-based ionic liquid (trioctyl(3/4-vinylbenzyl)phosphonium chloride) via3-(trimethoxysilyl)propyl methacrylate. The prepared columns were evaluated under hydrophilic inter-action liquid chromatography separation conditions, employing a sample mixture containing purine andpyrimidine bases and nucleosides. Detection was made by UV. The high efficiency of the original silicamonolith was preserved even after modification, and it reached values in the range of 98,000–174,000theoretical plates/m. The effects of the concentration of acetonitrile in the mobile phase, the presence ofadditives in the mobile phase, such as, acetic acid or ammonium acetate, and the pH of the mobile phaseon the separation of some selected analytes were investigated. The prepared columns showed differentseparation selectivity compared to silica, phenyl and sulfobetaine stationary phases.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1552
Číslo periodika v rámci svazku
JUN
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
53-59
Kód UT WoS článku
000431939400006
EID výsledku v databázi Scopus
2-s2.0-85045085429