Rapid fabrication of microextraction devices for direct determination of basic drugs in dried blood spots
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F18%3A00499020" target="_blank" >RIV/68081715:_____/18:00499020 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26310/18:PU130346
Výsledek na webu
<a href="http://www.ce-ce.org/user_uploads/program/CECE%202018%20Proceedings_WOS.pdf" target="_blank" >http://www.ce-ce.org/user_uploads/program/CECE%202018%20Proceedings_WOS.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rapid fabrication of microextraction devices for direct determination of basic drugs in dried blood spots
Popis výsledku v původním jazyce
A 3D-printed cutter was designed for rapid fabrication of supported liquid membrane (SLM) extraction devices compatible with injection system of commercial capillary electrophoresis (CE) instrument. Low cost and single use microextraction devices were fabricated from polypropylene micropipette tips with high precision (dimension variances ≤ 3% RSD). Practical applicability of the microextraction devices was examined by in-line coupling of SLM extractions to CE for direct analysis of four model basic drugs in dried blood spot extracts. Excellent repeatability of the hyphenated technique was achieved (RSD ≤ 7.6%), transfer of analytes across the SLM ranged from 23 to 73% and limits of detection were as low as 0.07 μg/mL.
Název v anglickém jazyce
Rapid fabrication of microextraction devices for direct determination of basic drugs in dried blood spots
Popis výsledku anglicky
A 3D-printed cutter was designed for rapid fabrication of supported liquid membrane (SLM) extraction devices compatible with injection system of commercial capillary electrophoresis (CE) instrument. Low cost and single use microextraction devices were fabricated from polypropylene micropipette tips with high precision (dimension variances ≤ 3% RSD). Practical applicability of the microextraction devices was examined by in-line coupling of SLM extractions to CE for direct analysis of four model basic drugs in dried blood spot extracts. Excellent repeatability of the hyphenated technique was achieved (RSD ≤ 7.6%), transfer of analytes across the SLM ranged from 23 to 73% and limits of detection were as low as 0.07 μg/mL.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA18-13135S" target="_blank" >GA18-13135S: Využití kapilární elektroforézy při analýze suchých krevních skvrn</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2018. 15th International Interdisciplinary Meeting on Bioanalysis
ISBN
978-80-904959-5-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
257-260
Název nakladatele
Ústav analytické chemie AV ČR, v. v. i.
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
15. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce